BQTF1 CARLO GAVAZZI, BQTF1 Datasheet

no-image

BQTF1

Manufacturer Part Number
BQTF1
Description
DC Tachometer/Frequency Input Module
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of BQTF1

No. Of Analog Inputs
2
For Use With
UDM Series Digital Panel Meter
Digital Panel Meters
Modular Indicator and Controller for pulse signals
Type UDM60
Type Selection
Slot A (measuring inputs)
TF1:
TF2:
Specifications are subject to change without notice
Product Description
µp-based
meter, dual 6-DGT LCD indi-
cator with analogue indica-
tors, for rate, speed, fre-
quency and period measure-
ments. Measuring ranges,
scaling and functions easily
programmable from the key-
pad or from the PC by
0.001Hz to 50kHz for
DC signals: PNP,
NPN, NAMUR, TTL,
free of voltage, con-
tacts, voltages up to
14VDC
0.001Hz to 50kHz for
AC signals: pick-up,
voltages up to
500VAC
digital
panel
Slot B (communication)
XX:
SX:
SY:
AV(*): Single analogue out-
(*):
means of optional UdmSoft
software. UDM60 includes
storage min-max functions
and double level protection
password. Housing for pan-
el mounting with front pro-
tection
NEMA12.
None
Serial port RS485
Serial port RS232
put, 0 to 20mA DC
and 0 to 10V DC
The two analogue
outputs cannot be
used at the same
time. It is possible to
plug in only one mod-
ule by instrument.
degree:
UDM60 DS ENG 261110
IP67,
How to order
UdmSoft-kit: software plus communication cable for pro-
gramming UDM60 by means of PC.
UdmSoft: software for programming UDM60 by means of
PC, downloadable from www.carlogavazzi.com.
• Dual 6-DGT µP-based controller with
• Dual rate, speed, frequency and period measurement
• Dual counter
• 0.001% RDG basic accuracy
• Range from 0.001Hz to 50kHz/20µs to 1000s
• Scalable inputs and counters
• Linearization of the inputs up to 16 points
• Special calculation functions
• NPN, PNP, NAMUR, TTL, Pick-up, free of voltage
• Up to 4 independent alarm set-points (optional)
• 20mA/10VDC analog output (optional)
• Serial port RS485 or RS232 (optional)
• MODBUS, JBUS communication protocol
• Front protection degree: IP67, NEMA12
• Backlighted LCD display
How to order
Model
Slot A
Slot B
Slot C
Slot D
Options
Slot C (communication and alarm)
XX:
R1:
R2:
R4:
R5:
AV(*): Single analogue out-
analogue indicators
contacts and AC signal inputs
None
Single relay output,
(AC1-8AAC, 250VAC)
Dual
(AC1-8AAC, 250VAC)
Dual
(AC1-8AAC, 250VAC)
+ dual open collector
output (NPN, 100mA)
4 relay outputs (AC1-
5AAC, 250VAC)
put, 0 to 20mA DC
and 0 to 10V DC
relay
relay
output,
output,
UdmSoft-kit
UDM60 XXX XX XX X XX
Slot D (power supply)
H:
L:
3:
Options
XX:
TX:
90 to 260V AC/DC
18 to 60V AC/DC
(24 to 48V AC/DC ±
25% according to UL)
10 to 28V DC
(12 to 24V DC ± 15%
according to UL)
None
Tropicalization
1

Related parts for BQTF1

BQTF1 Summary of contents

Page 1

Digital Panel Meters Modular Indicator and Controller for pulse signals Type UDM60 Product Description µp-based digital panel means of optional UdmSoft meter, dual 6-DGT LCD indi- software. UDM60 includes cator with analogue indica- storage min-max functions tors, for rate, speed, ...

Page 2

UDM60 Input specifications Analogue inputs Channels and variables BQ TF1 module 2, 0.001Hz to 50kHz for DC signals: PNP, NPN, NAMUR, TTL, free of volt- age contacts, voltages up to 14VDC. BQ TF2 module 2, 0.001Hz to 50kHz for AC ...

Page 3

UDM60 Input impedance and overloads Module Input type BQ TF1 NPN (DC) PNP (DC) NAMUR (DC) TTL (DC) Free of voltage contact (DC) BQ TF2 Pick-up (AC) Voltage (AC 100VAC Voltage (AC 500VAC Output specifications RS422/RS485 ...

Page 4

UDM60 Output specifications (cont.) measuring input 4000 V power supply input Analogue output (on request) Module Range mADC VDC Scaling factor Programmable within the entire retransmission range; allows to manage the retransmission ...

Page 5

UDM60 General specifications Operating temperature 0°C to +50°C (32°F to 122°F) (R.H. ≤ 90% non- condensing) Storage temperature -10°C to +60°C (-14°F to 140°F) (R.H. ≤ 90% non- condensing) Insulation reference voltage 300 V input) Insulation See table “Insulation between ...

Page 6

UDM60 List of selectable functions and variables Name F1 Frequency meter, tachometer F2 Period meter F3 Speed difference F4 Speed error ratio F5 Speed ratio Concentration of a liquid in a mix- F6 ture F7 Rotation sensing F8 Frequency meter ...

Page 7

UDM60 Wiring diagrams BQ TF1 Fig. 1 ENCODER NPN/PNP BQ TF1 Fig. 4 PNP and contact BQ TF1 Fig. 7 Auxiliary command Specifications are subject to change without notice BQ TF1 Fig. 2 NAMUR BQ TF1 Fig. 5 NPN/PNP UDM60 ...

Page 8

UDM60 Wiring diagrams (cont.) BQ TF2 Fig. 8 Pick-up max 100VAC Wiring diagrams for power supply BP H: power supply F1= 630mA T 250V 5x20mm Wiring diagrams of optional modules BO AV: analogue output (10V, 20mA DC TF2 ...

Page 9

UDM60 Wiring diagrams of optional modules (cont.) BO R4: dual relay output + dual open collector output: the load resistances (Rc) must be designed so that the close contact current is lower than 100mA; the VDC voltage must be lower ...

Page 10

UDM60 Front panel description Key-pad The programming of the configuration parameters and the display may be easily controlled by means of the 4 function keys enter the programming phase and to confirm ...

Page 11

UDM60 Modules Input modules Output modules BQ TF1, BQ TF2 BO AV Single analogue output 10V, 20mA DC Measuring inputs Output modules Single relay output Dual relay output Serial port modules RS485 ...

Related keywords