E53-Q Omron, E53-Q Datasheet
![no-image](/images/manufacturer_photos/0/4/494/omron_sml.jpg)
E53-Q
Specifications of E53-Q
Related parts for E53-Q
E53-Q Summary of contents
Page 1
Digital Controller E5AK Advanced Digital Controllers Ideal for Worldwide Use • Modular structure • High-accuracy: 100 ms sampling (for analog input) • Auto-tuning and fuzzy self-tuning • Conforms to international EMC and safety standards. • IP66/NEMA4 (indoor use) front face ...
Page 2
... The Digital Controller provides transfer outputs for the PV and other values and control outputs for the current outputs. Description Output Unit E53-R E53-S E53-Q E53-Q3 E53-Q4 E53-C3 E53-C3D E53-V34 E53-V35 Note: The Digital Controller uses a dedicated, high-resolution Output Unit. The E53-C Current Output Unit for the E5@X cannot be used with the Digital Controller. Description ...
Page 3
... Current Transformer E54-CT1 E54-CT3 Note required unless the heater burnout alarm function is used. Name Terminal Cover E53-COV0809 Note: The E53-COV0809 comes in a set with the two types of Terminal Covers listed on page 8. Unit Label Model Y92S-L1 Waterproof Packing Model Y92S-P4 The Waterproof Packing is provided with the Digital Controller. ...
Page 4
Input Ranges Platinum Resistance Thermometer Input (switch selectable) JPt100 °C −199.9 to 650.0 Range °F −199.9 to 999.9 Setting 0 Thermocouple Input (switch selectable) (See note.) °C −200 −100 Range 0 500.0 to 850 ...
Page 5
Characteristics Indication accuracy (See note 1.) Thermocouple: (±0.3% of indication value or ±1°C, whichever greater) ±1 digit max. Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. ...
Page 6
... Model E53-R Relay output E53-S SSR output E53-Q Voltage output E53-Q3 E53-Q4 E53-C3 Linear current output E53-C3D E53-V34 Linear voltage output E53-V35 Note: An output relay ( 250 VAC) is mounted on the position-proportional model. (When replacing, use the E53-R.) ■ Option Unit Ratings and Characteristics ...
Page 7
Nomenclature E5AK Operation Indicators • OUT1 Lights when the pulse output function assigned to control output 1 turns ON. • OUT2 Lights when the pulse output function assigned to control output 2 turns ON. • SUB1 Lights when the output ...
Page 8
... E54-CT1 120 min. Note: 1. Recommended panel thickness mm. 2. Maintain the specified vertical and horizontal mounting space between each Unit. Units must not be closely mounted vertically or horizontally. E54-CT3 5.8 dia. E5AK Panel Cutouts 110 min. E53-COV08 2.36 dia. 12 dia. 40x40 Two, M3 (depth ...
Page 9
... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required. ...
Page 10
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...