3204/CC/VH/TTRX/R/XXX/G/ENG EUROTHERM CONTROLS, 3204/CC/VH/TTRX/R/XXX/G/ENG Datasheet - Page 3

Process/Temperature Controller

3204/CC/VH/TTRX/R/XXX/G/ENG

Manufacturer Part Number
3204/CC/VH/TTRX/R/XXX/G/ENG
Description
Process/Temperature Controller
Manufacturer
EUROTHERM CONTROLS
Datasheet

Specifications of 3204/CC/VH/TTRX/R/XXX/G/ENG

No. Of Analog Inputs
2
No. Of Analog Outputs
3
No. Of Digital Inputs
3
No. Of Digital Outputs
4
Controller Output Type 1
Triac
Output Type
Triac, Relay
Control Operation
Auto/Manual, Ramp/Soak, Stand By, Valve Positioning
Control Output Current
0.75 A
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Process variable input
Calibration accuracy:
Sample rate:
Isolation:
Resolution (μV):
Resolution (effective bits):
Linearisation accuracy:
Drift with temperature:
Common mode rejection:
Series mode rejection:
Input impedance:
Cold junction compensation:
External cold junction:
Cold junction accuracy:
Linear(process) input range:
Thermocouple types:
Resistance thermometer types:
Bulb current:
Lead compensation:
Input filter:
Zero offset:
User calibration:
Notes
(1) Calibration accuracy quoted over full ambient operating range and for all
(2) Contact Eurotherm
AA relay
Type:
Rating:
Functions:
Current transformer input
Input range:
Calibration accuracy:
Isolation:
Input impedance:
Measurement scaling:
Functions:
Digital input (DigIn A/B, B not on 3216)
Contact closure:
Input current:
I
Functions:
Logic I/O module
Output
Rating:
Isolation:
Functions:
Digital input
Contact closure:
Isolation:
Functions:
Relay output channels
Type:
Rating:
Functions:
solation:
input linearisation types
alternative sensors
®
for details of availability of custom downloads for
<±0.25% of reading ±1LSD
4Hz(250ms)
264Vac double insulation from the PSU
and communication
<0.5μV with 1.6sec filter
>17 bits
< 0.1% of reading
<50ppm (typical) <100ppm (worst case)
48-62Hz, >-120db
48-62Hz, >-93dB
100MΩ
>30:1 rejection of ambient change
Reference of 0°C
<±1°C at 25°C ambient
-10 to 80mV, 0 to 10V with
100KΩ/806Ω external divider module
K, J, N, R, S, B, L, T, C, custom
download
3-wire Pt100 DIN 43760
0.2mA
No error for 22 ohms in all leads
Off to 59.9s
User adjustable over full range
2-point gain & offset
Form C (changeover)
Min 100mA@12Vdc, max 2A@264Vac
resistive
Control outputs, alarms, events
0-50mA rms, 48/62Hz. 10Ω burden
resistor fitted inside module
<1% of reading (Typical),
<4% of reading (Worst case)
By using external CT
<20Ω
10, 25, 50 or 100 Amps
Partial load failure, SSR fault
Open >600Ω, closed <300Ω
<13mA
None from PV or system
264Vac double insulated from PSU and
communications
Includes alarm acknowledge, SP2 select,
manual keylock, timer functions, standby
select, RSP select
ON 12Vdc@<44mA,
OFF <300mV@100μA
None from PV or system.
264Vac double insulated from PSU and
communications
Control outputs, alarms, events
Open >500Ω, closed <150Ω
None from PV or system
264Vac double insulated from PSU and
communications
Includes alarm acknowledge, SP2
select, manual, keylock, timer functions,
standby select, RSP select
Form A (normally open)
Min 100mA@12vdc, max 2A@264Vac
resistive
Control outputs, alarms, events
(2)
(1)
Triac output
Rating:
Isolation:
Functions:
Analogue output
OP1, OP2
Rating:
Accuracy:
Resolution:
Isolation:
Functions:
OP 3 (not on 3216)
Rating:
Accuracy:
Resolution:
Isolation:
Functions:
Remote setpoint input
Calibration accuracy:
Sample rate:
Isolation:
Resolution:
Resolution (effective bits):
Drift with temperature:
Common mode refection:
Series mode rejection:
Input impedance:
Normal input range:
Max input range:
Software features
Control
Number of loops:
Loop update
Control types:
Cooling types:
Modes:
Overshoot inhibition:
Alarms
Number:
Type:
Latching:
Output assignment:
Other status outputs
Functions:
Output assignment:
Setpoint programmer
Program function:
Start mode:
Power fail recovery:
Guaranteed soak:
Timer
Modes
Current monitor
Alarm types:
Indication type:
Custom messages
Number:
No of characters:
Languages:
Selection:
Recipes
Number:
Selection:
Notes
(3) Voltage output can be achieved by external adaptor
(4) By using recipes five SP programs can be stored
(3)
0.75A (rms) 30 to 264V(rms) resistive
load
264Vac double insulated
Control outputs, alarms, events
0-20mA into <500Ω
± (<1% of Reading + <100μA)
13.5 bits
264Vac double insulated from PSU and
communications
Module code C provides full 264Vac
double isolated
Control outputs, retransmission
0-20mA into <500Ω
±(<0.25% of Reading + <50μA)
13.6 bits
264Vac double insulated
Control outputs, retransmission
<±0.25% or reading ±1LSD
4Hz (250ms)
264Vac double insulation from instrument
<0.5mV (for 0-10V) or <2μA (for 4-20mA)
>14bits
<50ppm (typical) <150ppm (worst case)
48-62Hz, >-120dB
48-62Hz, >-90dB
Voltage: 223KOhm and Current: 2R49
0 to 10V and 4 to 20mA
-1V to 11V and 3.36mA to 20.96mA
1
250ms
PID, ON/OFF, VP
Linear, fan, oil, water
Auto, manual, standby, forced manual
High, low
4
Absolute high & low, deviation high, low
or band, rate of change
Auto or manual latching, non-latching,
event only
Up to four conditions can be assigned to
one output
Including sensor break, manual mode,
timer status, loop break, heater
diagnostics, program event
Up to four conditions can be assigned to
one output
1 program x 8 segments with 1 event
output
Servo from PV or SP
Continue at SP or Ramp back from PV
Inhibits dwell timing until PV within
limits
Dwell when setpoint reached
Delayed control action,
Soft start limits power below PV threshold
Partial load failure, over current, SSR
short circuit, SSR open circuit
Numerical or ammeter
15 scrolling text messages
127 characters per message max
English, German, French, Spanish, Italian
Active on any parameter status using
conditional command
5 recipes with 38 parameters
HMI interface, communications or
digital IO
(4)