32H8/CC/VH/LRR/X EUROTHERM CONTROLS, 32H8/CC/VH/LRR/X Datasheet - Page 2

Process/Temperature Controller

32H8/CC/VH/LRR/X

Manufacturer Part Number
32H8/CC/VH/LRR/X
Description
Process/Temperature Controller
Manufacturer
EUROTHERM CONTROLS
Datasheet

Specifications of 32H8/CC/VH/LRR/X

No. Of Analog Inputs
2
No. Of Analog Outputs
3
No. Of Digital Inputs
3
No. Of Digital Outputs
4
Controller Output Type 1
Voltage/SSR
Output Type
Logic, Relay
Control Operation
Auto/Manual, Ramp/Soak, Stand By, Valve Positioning
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Recipes
Using iTools, recipes can be created that may be used to change the
operating parameters of the 3200 simply by selecting a new recipe
using the 3200 HMI. This is very useful where multiple products are
processed using the same controller but require different
parameters to be set.
Timer
An internal timer is configurable as an interval timer, delay timer or
to provide a soft start for hot runner control.
Setpoint retransmission
Sending the setpoint or other parameters from the 3200 to slave
devices can be achieved either using conventional analogue
communications or using Master Modbus communications. Master
Modbus in the 3200 allows a broadcast of a single parameter to the
network.
A typical application is a setpoint being retransmitted to a number
of slave controllers in a multi-zone furnace.
Modbus communications
All units support both EIA232 and 2-wire EIA485 communications
using the Modbus protocol. The 3216 supports 4-wire EIA485.
Configuration adaptor
iTools configuration to all 3200 controllers can be achieved by using
a configuration adaptor. It provides iTools with the ability to
communicate with and configure devices without the need for any
power being connected.
iTools wizard
Used to simplify the set up of 3200 series controllers. The wizard
guides the user through the configuration process with interactive
help and graphical demonstrations of features.
SPECIFICATION
General
Environmental performance
Temperature limits
Humidity limits
Panel sealing:
Shock:
Vibration:
Altitude:
Atmospheres:
Electromagnetic compatibility (EMC)
Emissions and immunity:
Electrical safety
(BS EN61010):
Physical
Panel mounting
Weight
Panel cut-out dimensions
Panel depth
Operator interface
Type:
Main PV display:
Lower display
Status beacons:
Power requirements
Approvals
Transmitter PSU (not 3216)
Rating:
Isolation:
Communications
Serial communications option:
Protocol:
Isolation:
Transmission standard:
INSTALLATION CATEGORY II
The rated impulse voltage for equipment on nominal 230V mains is 2500V.
POLLUTION DEGREE 2
Normally, only non-conductive pollution occurs. Occasionally, however, a
temporary conductivity caused by condensation shall be expected
3216, 3208, 3204:
3208/h8/04:
Operation:
Operation:
Storage:
Storage:
3216:
3208:
3204:
32h8:
3216:
3208:
3204:
32h8:
3216:
3208:
3204:
32h8:
32h8:
3216:
All:
0 to 55°C
-10 to 70°C
5 to 90% RH non condensing
5 to 90% RH non condensing
IP65, Nema 4X
BS EN61010
2g peak, 10 to 150Hz
<2000 metres
Not suitable for use in explosive or
corrosive atmosphere
BS EN61326
Installation cat. II; Pollution degree 2
1/16 DIN
1/8 DIN
1/4 DIN
1/8 DIN, horizontal
250g
350g
420g
350g
45W x 45Hmm
45W x 92Hmm
92W x 92Hmm
92W x 45Hmm
90mm
LCD TN with backlight
4 digits, green
5 character starburst, green
9 character starburst, green
Units, outputs, alarms, active setpoint
100 to 240Vac, –15%, +10%,
48 to 62 Hz, max 6W
24Vac, -15%, +10%.
24Vdc, -15% +20% ±5% ripple voltage
max 6W
100 to 240Vac, –15%, +10%,
48 to 62 Hz, max 8W
24Vac, -15%, +10%.
24Vdc -15% +20% ±5% ripple voltage
max 8W
CE, cUL listed (file E57766), Gost,
DIN 3440 (3216 only)
Suitable for use in Nadcap and
AMS2750D applications under Systems
Accuracy Test calibration conditions
24Vdc, >28mA, <33mA
264Vac double insulated
Modbus RTU slave
Modbus RTU Master broadcast
(1 parameter)
264Vac, double insulated
EIA232 or EIA485 (2 wire)
EIA485(4 wire) on 3216 only

Related parts for 32H8/CC/VH/LRR/X