PRL-422NECL PULSE RESEARCH LAB, PRL-422NECL Datasheet - Page 2

Product Description:2-Ch.Translator,RS-422to NECL

PRL-422NECL

Manufacturer Part Number
PRL-422NECL
Description
Product Description:2-Ch.Translator,RS-422to NECL
Manufacturer
PULSE RESEARCH LAB
Datasheet

Specifications of PRL-422NECL

Rohs Compliant
NA
Lead Free Status / RoHS Status
na
*SPECIFICATIONS
PRL-422NECL and PRL-422NECL are equivalent modules.
*Since the high frequency signals to and from the 124Ω I/O ports can not be easily measured, the 124Ω I/O ports of these adapters are first cascaded using shielded twisted pair cables, Trompeter P/N PCGOW10PCG-36
or equivalent. Input signals are applied to the 50Ω inputs of the PRL-422NECL, and outputs of the PRL-422RS are terminated into 50Ω/-2V, using the PRL-550NQ5X, four-channel NECL Terminators, connected to a 50
Ω input sampling oscilloscope.
Notes:
(1). The 50Ω output rise and fall times were measured with both the Q and
waveform degradation will occur.
(2). f
550NQ4X, four channel NECL Terminators, connected to a sampling 'scope.
(3). Trompeter P/N CBBJR79.
(4). Trompeter P/N PCGOW10PCG-36
SYMBOL
MAX
t
t
SKEW1
SKEW2
f max
V
V
t
t
I
V
R
PLH
PHL
t
DC
r
DC
AC
is measured using the differential input mode(switch up). The differential outputs are first divided by four, using the PRL-255Ns, ÷2 and ÷4 frequency divider module, and then measured using the PRL-
/t
TT
in
f
Fig. 1 PRL-422NECL to RS422 Translator
AC/DC Adaptor Input Voltage
Propagation Delay to output ↑
Propagation Delay to output ↓
Maximum Clock Frequency 2
Rise/Fall Times 1 (20%-80%)
Input Termination Voltage
Skew from unit to units
Skew between outputs
DC Input Voltage
Output Connector
DC Input Current
Input Resistance
Input Connector
PARAMETER
Output Cables
Input Cables
Weight
(0 o C ≤ ≤ ≤ ≤ T
Size
A
≤ ≤ ≤ ≤ 35 o C)
Q
outputs terminated into 50Ω/-2V. If one output is not terminated, both the rise and fall times will increase by approximately 15%, and output
400
± 7.5
Min
122
103
PRL-422RS
1.3x2.9x3.9
124 Ω TP 4
50 Ω Coax
30/-130
Triax 3
SMA
2000
2000
± 8.5
Typ
124
115
750
600
NA
20
40
7
60/-150
Max
126
± 12
127
850
200
400
Fig. 2 PRL-422RS to NECL Translator
1234 Francisco Street, Torrance, CA 90502
± 7.5
49.5
Tel: 310-515-5330 Fax: 310-515-0068
Min
-1.8
103
400
Email:
PRL-422NECL
1.3x2.9x3.9
124 Ω TP 4
50 Ω Coax
sales@pulseresearchlab.com
www.pulseresearchlab.com
30/-250
Triax 3
SMA
2000
2000
± 8.5
Typ
115
NA
600
50
20
40
-2
7
60/-300
Max
50.5
-2.2
± 12
127
200
400
UNIT
MHz
mA
Oz
in.
ps
ps
ps
ps
ps
V
V
V

Related parts for PRL-422NECL