WV468-2000.V1 EUROTHERM CONTROLS, WV468-2000.V1 Datasheet

Isolation Amplifier

WV468-2000.V1

Manufacturer Part Number
WV468-2000.V1
Description
Isolation Amplifier
Manufacturer
EUROTHERM CONTROLS
Datasheets

Specifications of WV468-2000.V1

Width
0.5"
Peak Reflow Compatible (260 C)
Yes
Output Accuracy
± 0.05% Of FS
Signal Input Type
Selectable Current Or Voltage
Supply Voltage
24VDC
Configuration Setup
DIP Switch
Iso-amp Mounting Type
DIN Rail
Display Alarm Type
2 Relay
Input Accuracy
± 0.015% Of FS
Leaded Process Compatible
Yes
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SLIMPAK
WV468
AC Voltage/Current Input
Isolating Signal Conditioner
High Accuracy Signal Conditioner with an
Isolated DC Voltage or Current Output
Benefits
Lower Power Requirements
Optional E-mail
Notification of Alarms
with Smart Power Control
True RMS Input
Improved Accuracy
Description
The Ultra SlimPak II is an exciting new line of isolating signal conditioners from Action Instruments with
greater accuracy and better stability than virtually any other signal conditioners on the market today. The
Ultra SlimPak II features Smart Power, which eliminates wasted power for low loop resistance loads in the
current output mode.
The WV468 has both RMS voltage and RMS current input ranges. Eight AC voltage input ranges (50mV,
150mV, 500mV, 5V, 20V, 50V, 150V & 250V) are DIP switch selectable. Each of these ranges has at least
95% zero and span adjustment. Two AC current input ranges (20mA and 100mA) are also available. Outputs
include 0-10V, 0-20mA and 4-20mA. The WV468 also supports reverse output mode.
®
II

Related parts for WV468-2000.V1

WV468-2000.V1 Summary of contents

Page 1

... Lower Power Requirements The WV468 has both RMS voltage and RMS current input ranges. Eight AC voltage input ranges (50mV, with Smart Power Control 150mV, 500mV, 5V, 20V, 50V, 150V & 250V) are DIP switch selectable. Each of these ranges has at least 95% zero and span adjustment ...

Page 2

... Ethernet connection and the optional WVC16 WebView Communica- tions Interface module. Alarms When used with the optional WVC16 commu- nications module, the WV468 supports alarms, which can be configured as high limit, low limit and a timer for routine maintenance. WV16 Communications Interface (Optional) ...

Page 3

Function Input Ranges Output Ranges 250V 150V 50V 20V Key: 5V 500mV 150mV 50mV 100mA 20mA Key Closed Pin Description 11 DC Power (+) 12 DC Power ...

Page 4

... Effective span turndown: > 95% Turn-Up/Turn-Down 80% (90% to ±0.25%) Ordering Information Specify: 1. Model: WV468-2000 2. Optional Custom Factory Calibration (specify C620, see required settings under "Calibration, page 2). 3. Accessories. Accessories All WV Series modules will mount on standard TS35 (model MD03) DIN rail. In addition, the following acces- ...

Related keywords