SV150115 CARLO GAVAZZI, SV150115 Datasheet

no-image

SV150115

Manufacturer Part Number
SV150115
Description
Signal Conditioning, Isolation Amplifiers
Manufacturer
CARLO GAVAZZI
Datasheet
Specifications are subject to change without notice (11.06.03)
Level Sensors
Amplifier, Capacitive
Types SV 150/250, SV 160/260
Product Description
Level
capacitive sensors, types VR
and VRY. The relays can con-
Type Selection
Plug
Circular
Input Specifications
Sensitivity
Sensor voltage
Sensor current
Sensor short-circuit current
General Specifications
Indication for
Environment
Approvals
CE-marking
Output ON
Power supply
Degree of protection
Pollution degree
Operating temperature
Storage temperature
control
SV 150/250
Output
SPDT
DPDT
SPDT
DPDT
Not activated
relays
Activated
for
Function
Discharging
Discharging
Charging
Charging
trol one or two levels of
charging (SV 160/260) or dis-
charging (SV 150/250).
Depends on sensor type
and material
Max. 24 VDC
Terminal 6 is negative
Min. 15 mA, max. 20 mA
Max. < 5 mA
Max. 45 mA
LED, red
LED, green
(only SV 150/250)
IP 20 B
3 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
UL, CSA
Yes
SV 160/260
Supply: 24 VAC
SV 150 024
SV 250 024
SV 160 024
SV 260 024
Supply: 115 VAC
SV 150 115
SV 250 115
SV 160 115
SV 260 115
• Level control for solid, fluid, or granulated
• SV 150/250: Max./min. control of DISCHARGING
• SV 160/260: Max./min. control of CHARGING
• Factory-set sensitivity
• For capacitive sensors VR.. and VRY..
• 10 A SPDT or 8 A DPDT output relay
• LED-indication: SV 150/250: Power supply and relay ON
• AC or DC power supply
Ordering Key
Housing
Output
Power supply
Supply Specifications
Power supply AC-types
Power supply DC-types
Rated operational voltage
Rated insulation voltage
Rated impulse withstand
Rated operational voltage 724 24 VDC ±15% (pin 2 pos.)
Rated insulation voltage
Rated transient protection volt. 800 V (1.2/50 µs)
substances
through pin 2 & 10
voltage
SV 160/260: Relay ON
Supply: 230 VAC
SV 150 230
SV 250 230
SV 160 230
SV 260 230
230 230 VAC ± 15%
115 115 VAC ± 15%
024 24 VAC ± 15%
Overvoltage cat. II (IEC 60664)
4 kV (1.2/50 µs)
(line/neutral)
Installation cat. II (IEC 60664)
None
SV 150 024
2.0 kVAC (rms)
Supply: 24 VDC
SV 150 724
SV 250 724
SV 160 724
SV 260 724
1

Related parts for SV150115

SV150115 Summary of contents

Page 1

Level Sensors Amplifier, Capacitive Types SV 150/250, SV 160/260 SV 150/250 Product Description Level control relays for trol one or two levels of capacitive sensors, types VR charging (SV 160/260) or dis- and VRY. The relays can con- charging (SV ...

Page 2

SV 150/250, SV 160/260 Output Specifications Output Rated insulation voltage Contact ratings (Ag-CdO) Resistive loads Small inductive loads Mechanical life Electrical life Operation frequency Insulation voltages Rated insulation voltage Rated impulse withstand voltage Mode of Operation Max. and/or min. control ...

Page 3

SV 150/250, SV 160/260 Operation Diagrams SV 150/250 DISCHARGING Example 1 Power supply Max. Min. Relay on Example 2 Power supply Max./Min. Relay on Accessories Sensors: Types VR and VRY Bases Hold down spring Base covers Front mounting bezel Specifications ...