MINI MCR-SL-R-UI Phoenix Contact, MINI MCR-SL-R-UI Datasheet
MINI MCR-SL-R-UI
Specifications of MINI MCR-SL-R-UI
Related parts for MINI MCR-SL-R-UI
MINI MCR-SL-R-UI Summary of contents
Page 1
... INTERFACE Data Sheet 102807_en_05 Description The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6.2 mm and converts potentiometer positions as a percentage to an analog standard signal. If the potenti- ometer range cannot be utilized to the full, an externally ac- cessible slide switch is used to set the upper and lower poti- position end values ...
Page 2
... MINI MCR-SL-PTB 2864134 MINI MCR-SL-PTB-SP 2864147 2866983 MINI-PS-100-240AC/24DC/1.5/EX 2866653 100 Ω ... 100 kΩ < 3 ... ... ... ... 0 V 12.5 V Approx. 12 ... ... ... ... Approx > 10 kΩ (at 500 Ω) < < 500 Ω (20 mA) Configurable 0 % ... 105 % 19 ... < (for 24 V DC) < 500 mW MINI MCR-SL-R-UI(-SP) Pcs. Pkt Pcs. Pkt PHOENIX CONTACT ...
Page 3
... Any IP20 6 93 102.5 mm PBT green Screw connection 2 0.14 mm ... 2 0.2 mm ... 2 1.5 kV (50 Hz, 1 min.) -20 °C ... 65 °C -40 °C ... 85 °C CE-compliant applied for OUT UI 5 GND1 6 UB GND2 ME 6,2 TBUS-... MINI MCR-SL-R-UI(-SP) Spring-cage conn 0.2 mm ... 2 0.2 mm ... 2 PHOENIX CONTACT 3 ...
Page 4
... Press/Slide button for adjustment 4 Diagnostics LED Groove for ZBF 6 Zack marker strip Output: Standard signals , ³ Supply voltage ° ° Connection option for DIN rail connector 9 DIP switch S1 10 DIP switch S2 11 Universal snap-on foot for EN DIN rails MINI MCR-SL-R-UI(-SP) 4 PHOENIX CONTACT ...
Page 5
... When using T-BUS DIN rail connectors, first insert the DIN rail connector in the DIN rail to bridge the power supply (see assembly). Direction: Snap-on foot below and connector left. MINI MCR-SL-R-UI(-SP) WARNING In potentially explosive areas, snap the modu- le onto the DIN rail and connect the cables only when the power is disconnected ...
Page 6
... Insert the wires in the corresponding connection terminal block. Use a screwdriver to tighten the screw in the opening above the connection terminal block Spring-cage connection (MINI MCR-...-SP) Insert a screwdriver in the opening above the connection ter- minal block. Insert the wires in the corresponding connection terminal block. MINI MCR-SL-R-UI(-SP) 6 PHOENIX CONTACT ...
Page 7
... End of measuring range Start of measuring range ON • = OFF = MINI MCR-SL-R-UI(-SP) CAUTION: Electrostatic discharge The module contains components that can be damaged or destroyed by electrostatic di- scharge. When handling the module, observe the necessary safety precautions against elec- trostatic discharge (ESD) according to EN 61340-5-1 and EN 61340-5-2. ...
Page 8
... Teach-In value is reset to the upper potentiometer value. After deleting the values suc- cessfully, the LED flashes twice. If the button is pressed for more than 3 seconds, both Teach In values are reset and the entire potentiometer range ( 100 %) is used. MINI MCR-SL-R-UI(-SP) 8 PHOENIX CONTACT ...
Page 9
... Height adjustment of a lifting platform with setpoint and actual value PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany 102807_en_05 IST SOLL 0...10V 0...10V Controller 5 Control system 24V Mains voltage Phone: +49-(0) 5235-3-00 • Fax: +49-(0) 5235-3 www.phoenixcontact.com MINI MCR-SL-R-UI(-SP) 9 ...