H7AN-4D-AC100-240 Omron, H7AN-4D-AC100-240 Datasheet - Page 13

COUNTER DIGITAL LED

H7AN-4D-AC100-240

Manufacturer Part Number
H7AN-4D-AC100-240
Description
COUNTER DIGITAL LED
Manufacturer
Omron
Datasheet

Specifications of H7AN-4D-AC100-240

Rohs Compliant
YES
Digit Height
72mm
Supply Voltage Range
100VAC To 240VAC
Counting Speed
30Hz
Operating Temperature Range
-10°C To +55°C
No. Of Digits / Alpha
4
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Note: These settings are the defaults.
Note: These settings are the defaults.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
0, 1, 8, 9
(See note.)
2
3
4, 5
6
7
0, 1
2
3
4, 5
6
7
8
9 (See note.)
SW1
SW1
position
position
Switch
Switch
(A) Counting function selector
(B) Counting function selector
Note: 1. The panel cutouts for the H7AN are as shown (according to DIN437000).
Up/Down A (command inputs)
Up/Down B (individual inputs)
Up/Down C (differential phase inputs)
Up/Down D (command inputs)
Up/Down E (individual inputs)
Up/Down F (differential phase inputs)
Up/Down A (command inputs)
Up/Down B (individual inputs)
Up/Down C (differential phase inputs)
Up/Down D (command inputs)
Up/Down E (individual inputs)
Up/Down F (differential phase inputs)
DOWN
UP
2. The recommended mounting panel thickness is from 1 to 5 mm.
3. Use the mounting bracket (sold together) to mount the digital counter.
72
Function
Function
72
19
4
10
15
10.5
83
Two mounting brackets
115
Note: These settings are the defaults.
Note: These settings are the defaults.
0, 7, 8, F
(See note.)
1, 9
2, A
3, B
4, C
5, D
6, E
(See note.)
1
2
3
4
5
6
8, F
9
A
B
C
D
E
SW2
SW2
0, 7
position
position
Switch
Switch
(A) Operating mode selector (1-stage preset
(B) Operating mode selector (2-stage preset
models)
models)
@67.6
N (count stop, output hold)
F (overcount, output hold)
C (automatic reset, one-shot output)
R (automatic reset, one-shot output 1)
K (overcount reset, one-shot output)
P (automatic reset, one-shot output 2)
Q (automatic reset, one-shot output 3)
First-stage
output hold
First-stage
one-shot
output
M3.5 screw
87.6
Panel Cutouts
Second-stage function
N (count stop, output hold)
F (overcount, output hold)
C (automatic reset, one-shot output)
R (automatic reset, one-shot output 1)
K (overcount reset, one-shot output)
P (automatic reset, one-shot output 2)
Q (automatic reset, one-shot output 3)
N (count stop, output hold)
F (overcount, output hold)
C (automatic reset, one-shot output)
R (automatic reset, one-shot output 1)
K (overcount reset, one-shot output)
P (automatic reset, one-shot output 2)
Q (automatic reset, one-shot output 3)
100 min.
(When N units are
flush-mounted horizontally.)
68
(n-1) × 72 + 70 min.
(including a tolerance of 2 mm)
+0.7
−0
Function
68
+0.7
−0
68
+0.7
−0
H7AN
82
13

Related parts for H7AN-4D-AC100-240