CJ1W-NC434 Omron, CJ1W-NC434 Datasheet - Page 393
CJ1W-NC434
Manufacturer Part Number
CJ1W-NC434
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet
1.CJ1W-NC214.pdf
(601 pages)
Specifications of CJ1W-NC434
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 393 of 601
- Download datasheet (14Mb)
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Operation status and Data Transfer
*1. "Always only" refers to the parameter data, memory operation data and memory operation condition data that
PCU setup in
SOFTWARE
EXCLUSIVE
SOFTWARE
EXCLUSIVE
mode (Data
is always rewritable.
mode (Test
Operating
Initializing
operation
Transfer)
progress
Normal
status
Run)
The PCU has these operating status. Operation you can perform with the PLC varies
depending on the operation status.
The table below shows the relationship between the operation status of the PCU in terms of
data transfer and the transfer means.
If a warning occurs as a result of a data check, turn ON the warning reset once, and transfer the
normal data again.
again. Doing so may result in an unexpected operation because the data since the warning
occurred has not been transferred.
All data is transferred when you execute the IOWR or IORD instructions. Therefore, pay careful
attention when you execute the IOWR or IORD instructions consecutively within the same scan
because the error code at the time of the transfer may not be output.
Do not execute any command, such as data save or start, without transferring the normal data
Precautions for Correct Use
From the status in which you turn ON the
power supply or execute a restart until the
unit starts.
In this status, the PCU ready (n+11 word,
bit 15) is OFF.
The PCU Setup Memory area (n word, bit
15) is ON and the PCU ready is OFF.
A mode by a CX-Programmer command.
In this mode, data transfer by CX-
Programmer is possible.
Ladder program output is disabled.
A mode by a CX-Programmer command.
In this mode, operation by CX-Programmer
is possible.
Ladder program output is disabled.
The PCU ready is ON.
Regardless of the means, you can specify
writing only the data that is always
reflected.
You can read all data types.
Explanation of operating status
(Always only)
Data transfer
bit
−
√
−
−
√
8-1 Outline of Data Transfer
*1
Transfer means
(Always only)
IOWR/IORD
√: Permitted, −: Not permitted
−
−
−
−
√
*1
(Always only)
(Always only)
Programmer
CX-
−
−
√
√
√
8-20
*1
*1
8
Related parts for CJ1W-NC434
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
ANALOG IN, CJ1, 4CH, HIGH SPPE
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
High Speed Pulse Train 2 Axes
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
High Speed Pulse Train 2 Axes
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
High Speed Pulse Train 4 Axes
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CJ Profinet Master
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Ethernet I/P Module
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
HIGH SPEED COUNTER 500Khz 2 CH
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Isolated Universal Analog 4pt
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CJ1 CompoNet Master
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: