6ED1 052-2FB00-0BA5 SIEMENS, 6ED1 052-2FB00-0BA5 Datasheet - Page 69

LOGIC MODULE, 6 IP/4 OP, 110/230VAC

6ED1 052-2FB00-0BA5

Manufacturer Part Number
6ED1 052-2FB00-0BA5
Description
LOGIC MODULE, 6 IP/4 OP, 110/230VAC
Manufacturer
SIEMENS
Datasheet

Specifications of 6ED1 052-2FB00-0BA5

No. Of Analogue Outputs
2
No. Of Digital Inputs
8
No. Of Digital Outputs
4
Ip/nema Rating
IP20
Approval Bodies
CSA, FM, IEC, UL, VDE
External Depth
55mm
External Length / Height
90mm
Overview
Technical specifications
SIWAREX P
Main applications
Intrinsically-safe load cell
powering
Stand-alone (without SIMATIC)
Integration in:
• S5-90/-95U/-100U
• S5-95U/DP (PROFIBUS master)
• S5-115U/-135U/-155U
• S7-300
• S7-400
• M7-300
• M7-400
• C7
Communication interfaces
Process interfaces
• Digital outputs
• Analog output/analog input
Remote display connection
(via serial interface)
Measuring properties
Error limit according to DIN 1319-1
of full-scale value at 20 °C
Internal resolution
Data format for weight values
Number of
measurements/second
Filter
Weighing functions
• Weight values
• Limits
10 K
• Load measurement on cranes
• Overload protection
• Belt tensioning devices
• Platform scales
• Fill level (containers/bins)
Optional (Ex-l)
Yes
Direct integration
Through ET 200U
Through ET 200U
Through ET 200U
Through ET 200U
Through ET 200U
Through ET 200U
Through ET 200U
SIMATIC S5 bus
TTY
2 limits/fault
Yes / No
Yes
Gross
0,1 %
20.000
2 byte (fixed-point)
10
0.0625 -2 Hz
Gross
2 (min./max.)
SIWAREX P is a weighing and force measuring system for simple
tasks. It can be used for all kinds of industrial measurements.
SIWAREX P has the design of the SIMATIC S5-100U program-
mable controllers and can be used as a stand-alone device or
also integrated directly in a SIMATIC S5-90U, -95U or -100U
programmable controller.
Note:
Bus module available as spare part; see I-button with the acces-
sories ordering data.
SIWAREX P
Integral display and operator
panel
Module parameterization
IP degree of protection to
DIN 60 529; IEC 60 529
Load cell powering
• Supply voltage U
• Max. supply current
• Permissible load resistance:
Permissible load cell
characteristic
Permissible range of measuring
signal (at greatest set
characteristic)
Max. distance of load cells
Supply voltage 24 V DC
• Rated voltage
• Max. current consumption
Serial port 1
• Baud rate
• Parity
• No. of data bits/stop bits
• Signal level
• Protocols
Binary outputs
- R
- R
- R
- R
Lmin
Lmax
Lmin
Lmax
s
(rated value)
SIMATIC S7-300
Siemens ST 70 News · 2006
Yes
Built-in LCD +
Membrane keyboard
IP20
10 V
> 60
< 4010
With Ex(i) interface:
> 87
< 4010
Up to 3 mV/V
0 to 33 mV
500 m
(300 m in Ex area)
24 V DC
300 mA
TTY (serial 20 mA):
9600 baud
straight
8/1
Passive, floating
3964R / RK512
(send only on request)
Number: 2 (relay)
Max. switching voltage: 120 V DC
50 V AC
Max. current: 1 A
(resistive load)
160 mA or
115 mA (Ex area)
Function modules
0.5 V DC
SIWAREX P
4/41
4