DM3600U/S2 STATUS, DM3600U/S2 Datasheet - Page 2

no-image

DM3600U/S2

Manufacturer Part Number
DM3600U/S2
Description
PANEL METER, UNIVERSAL, 20/35V DC
Manufacturer
STATUS
Datasheet

Specifications of DM3600U/S2

No. Of Digits / Alpha
6
Meter Function
Flow And Totalizer
Supply Voltage Range
20VDC To 35VDC
Power Consumption
6VA
Svhc
No SVHC (15-Dec-2010)
Display Technology
LED
Panel Cut-out Size
92 X
Digital Instrument Type
Multifunction
Rohs Compliant
Yes
Display Font Colour
Red
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
I N T E L L I G E N T D I G I TA L I N D I C ATO R , W I T H T F M L . . . .
UNIVERSAL INPUT TYPES
Sensor
mA
RTD
T/C
mV
Volts
Minimum Span
CURRENT INPUT
Basic Accuracy
Thermal Drift
Input Impedance
Linearity
A 19.5 V ± 0.5 V @ 25 mA isolated power supply is available to
power the current loop.
RTD
Sensor Range
Linearisation
Basic Accuracy
Thermal Drift
Excitation Current
Lead Resistance Effect
Max Lead Resistance
Linearisation
Cold Junction Error
Cold Junction Tracking
Cold Junction Range
Thermal Drift
VOLTAGE INPUT
Basic Accuracy
Thermal Drift
Input Impedance
Linearity
Range
*Notes:
1.
2.
3.
4.
Two isolated digital inputs are available to reset latched
alarms, reset peak and valley memories, reset total or for
customised use with TFML.
Accuracy
R E M O T E D I G I TA L S O P T I O N
S P E C I F I C AT I O N S @ 2 0 ° C
Custom can be up to 60 co-ordinate pairs or up to 7
segments of 15th order polynominal
Full accuracy for any span > 10 % of range
Accuracy true for (500 to 1760) °C
Accuracy true for (400 to 1650) °C
Zero
Span
Zero
Span
Range and Linearisation
(4 to 20) mA, ± 20 mA, ± 10 mA
Pt100, Ni120, Custom*¹
K, J, T, R, S, B, N, L, B, E,
Custom*¹
± 100 mV
± 10 V, ± 5 V, (1 to 5) V, ± 1 V
Any span within the range can
be selected, but the
recommended span is > 10 %
of range
0.05 % FS ± 0.05 % of reading*²
0.02 %/°C
20 Ω
Linear, X½, X
(-200 to 850) °C (18 to 390 Ω)
BS EN60751/JISC1604/Custom*¹
0.1 °C ± 0.05 % of reading*²
0.004 Ω/°C
0.01 %/°C
1 mA
0.002 °C/Ω
50 Ω/leg
± 0.04 % FS or ± 0.04 % reading or
± 0.5 °C, whichever is greater*²
BS 4937/IEC 584 3/Custom*¹
± 0.5 °C
0.05 °C/°C
(-20 to 60) °C
4 µV/°C
0.002 %/°C
0.04 % FS ± 0.04 % of reading*²
1 MΩ
Linear, X
± 100 mV, ± 1 V, ± 5 V, ± 10 V,
(1 to 5) V
0.01 %/°C
½
, X
3
3
/
/
2
2
, X
, X
5
5
/
/
2
2
, Custom*¹
, Custom*¹
PLUG IN AND PLAY OPTIONS
Simple plug in pre-calibrated units, no dismantling or re-calibration.
POD-3000/02
Two independent relay outputs
Contacts
Ratings
Maximum Load
Maximum Power
Maximum Switching
Electrical Life
Mechanical Life
Termination
Relay can be set as High/Low or deviation alarm on rate or total, or
configured to 100 ms output pulse at pre-determined total intervals.
POD-3000/03 ISOLATED RE-TRANSMISSION
Ranges
Minimum Current Output
Maximum Current Output
Accuracy
Resolution
Max. Output Load
Max. Ext. Supply Voltage
Voltage Effect
Ripple Current
Isolation
Stability
Termination
VOLTAGE OUTPUTS
Voltage Outputs may be obtained by connecting an external
resistor and selecting the appropriate current range, as shown
in the table below.
GENERAL
Filter (seconds)
Power Supply
Power Consumption
Isolation (Tested to)
ENVIRONMENTAL
Sealing to Panel
Ambient Operating Range
Ambient Storage
Ambient Humidity
EMC
Emissions & Immunity
Safety
O U T P U T O P T I O N S
RESISTOR
1 KΩ
500 Ω
250 Ω
DUAL RELAY ALARM/PULSE
Standard
Standard
Optional
Optional
Active
Passive
S1
S2
CURRENT
(0 to 10) mA
(0 to 20) mA
(4 to 20) mA
2 x changeover relays with
common wiper
AC
5 A @ 250 V
1250 VA
253 V
10*
50 million operations
5 way tension clamp connector
Screw terminals
(0 to 100) mA (Active or Passive)
(0 to 20) mA (Active or Passive)
(4 to 20) mA (Active or Passive)
0 mA
23 mA
0.07 % F.S.
1 part in 30 000
30 V (Passive mode)
500 VAC
1 µA/°C
1 KΩ
[(Vsupply-2)/22] KΩ
0.2 µA/V
< 3 µA
5 way tension clamp connector
Screw terminals
None, Programmable (fixed),
Adaptive
(90 to 264) VAC (50 to 60) Hz*
(20 to 35) VDC
10 VA (worst case) 6 VA typical
I/O ports 500 V
Supply to I/O 3750 V
IP65
(-30 to 60) °C
(-50 to 85) °C
(10 to 90) % RH
BS EN61326
BS EN61010-1
UL Approved
5
operations at rated load
(0 to 10) V
(0 to 10) V
(1 to 5) V
OUTPUT
DC
5 A @ 30 V
150 W
125 V
8

Related parts for DM3600U/S2