INFRESCO P 6KW UNITED AUTOMATION, INFRESCO P 6KW Datasheet - Page 4

INFRESCO, PIR 6KW

INFRESCO P 6KW

Manufacturer Part Number
INFRESCO P 6KW
Description
INFRESCO, PIR 6KW
Manufacturer
UNITED AUTOMATION
Datasheet

Specifications of INFRESCO P 6KW

Operating Temperature Max
40°C
Operating Temperature Min
-20°C
Approval Bodies
CE
External Depth
75mm
External Length / Height
130mm
Ip/nema Rating
Load Power
For Use With
Quartz Infrared Halogen Lamps
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
WIRING OPTION 1
WIRING OPTION 2
DIMENSIONS
Commissioning
Turn the lamp on-time preset (VR2) fully anti-clockwise to select ‘walk test’ mode. Check
the PIR sensitivity preset (VR3) is set to approximately the half-way position (factory
default). The temperature set point preset (VR1) is ignored in ‘walk west’ mode.
Switch on the mains supply to the unit. The controller waits 60 seconds to allow the PIR
sensor to stabilise. The detection area can then be walk tested to verify the PIR’s
coverage. Each time the PIR detects sufficient movement, the lamps will switch on for 5
seconds.
Note: Each time the lamps switch off, the PIR is inhibited for 5 seconds to
prevent changes in infrared energy given off by the lamps from causing a false
activation.
Once the detection area and range have been verified, adjust the on-time preset to
between 5 and 30 minutes. This will automatically disable ‘walk test’ mode.
The temperature set point preset should now be set as required.
Note: If the ambient temperature exceeds the set point temperature, the lamps
are inhibited.
The PIR sensitivity preset can also be adjusted if necessary. Turning the preset
clockwise increases the sensitivity.
Note: Increasing the PIR sensitivity may also increase the likelihood of PIR false
activations.