INFRESCO T 6KW UNITED AUTOMATION, INFRESCO T 6KW Datasheet - Page 2

INFRESCO, TIMER 6KW

INFRESCO T 6KW

Manufacturer Part Number
INFRESCO T 6KW
Description
INFRESCO, TIMER 6KW
Manufacturer
UNITED AUTOMATION
Datasheet

Specifications of INFRESCO T 6KW

Operating Temperature Max
65°C
Operating Temperature Min
-20°C
Approval Bodies
CE
External Depth
75mm
External Length / Height
130mm
External Width
130mm
For Use With
Infra Red Heating Lamps, Garden
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Adjust the lamp on-time preset (VR2) to between 1 and 30 minutes as required.
Switch on the mains supply to the unit. Press the push button on the front of the unit
Technical Specification
Mains Voltage
Operation Current
Power Consumption
Set Time Period
Factory Set Temperature trip point
Max load at 20° C ambient
Max Unit Operating Temperature
IP Rating
Gland Diameter (Fitted)
4 Lamp Installation
WARNING: THIS UNIT MUST BE EARTHED
Troubleshooting
Problem: Lamps do not switch on.
Solution:
1)
2)
3)
Problem: Lamps do not switch off.
Solution:
1)
2)
It is recommended that installation and maintenance of this equipment should be done with reference
to the current edition of the I.E.E. wiring regulations (BS7671) by suitably qualified/trained personnel.
These regulations contain important requirements regarding safety of electrical equipment (for
International Standards refer to I.E.C/ directive IEC950).
Operation
to switch on the lamps.
1 Southport Business Park
Kew
Southport, PR8 4HQ
ENGLAND
Check the LINE and LOAD wiring connections to the unit and ensure the mains supply is
switched on. Go to 2) if fault still exists.
Check the lamps/Lamp fittings. If possible, fit a known working lamp. Go to 3) if fault still exists.
Isolate the mains supply then check, and replace if necessary, the PCB-mounted fuse (F1). If the
fault still exists, contact your supplier.
Check the on-time setting is set correctly. Any adjustment will only take effect the next time the
lamp is activated. Go to 2) if fault still exists.
Check the
UNITED AUTOMATION LIMITED
www.infresco.co.uk
Tel: 0044 (0) 1704 – 516500 Main
6 kW
230Vac +/- 10% 50 Hz
Max 25
50mA
1 to 30 Minutes
20° C
65° C
65
Max Cable Entry 2.5mm²
Must be fitted in Parallel
Tel: 0044 (0) 1704 - 516516 Sales
Fax: 0044 (0) 1704 – 516501
Enquiry@united-automation.com
Users & Installation Manual
Infresco T 6.0kW
X10709
RoHS Compliant
2002/95/EC
Directive
Issue 1
for
03/09/07

Related parts for INFRESCO T 6KW