MCR-1CLP-1-1-00 Phoenix Contact, MCR-1CLP-1-1-00 Datasheet

no-image

MCR-1CLP-1-1-00

Manufacturer Part Number
MCR-1CLP-1-1-00
Description
INTERFACE ANALOG
Manufacturer
Phoenix Contact
Datasheet

Specifications of MCR-1CLP-1-1-00

Input Type
4 - 20mA
Output Type
4-20mA
No. Of Output Channels
1
Accuracy
± 0.1%
Approval Bodies
UL Recognised
External Depth
114.5mm
External Length / Height
99mm
External Width
12.5mm
Input Voltage Max
30V
Isolation Input
Isolated
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Multi-Channel Passive Isolator
MCR-...CLP-I/I-00
• Electrical isolation without additional
• Current signals 0(4)...20 mA
• 1-, 2- and 4-channel versions
1. Description
the electrical isolation and processing of analog
0(4)… 20 mA standard current signals. The blocks
provide electrical isolation between the control
electronics and process I/O. In addition, interference
signals above 75 Hz are effectively suppressed.
auxiliary power. The modules obtain this power from
the input signal.
rails in accordance with EN 50 022.
current-driving voltage of the measuring transducer U
is sufficient for driving the maximum current of 20 mA
over the passive isolator with the power loss of
U
This means:
U
Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
V
B
power supply
MCR-1,2,4CLP-I/I-00 passive isolators are used for
Input and output circuit do not require separate
The modules are snapped onto symmetrical DIN
When using passive isolators, ensure that the
= 2.5 V and the load R
U
E
U
= 2.5 V + 20 mA
B
I
I
Phone +49 - 52 35 - 3 00 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com
U
I
E
MCR-1CLP
UV = 2.5 V
B
*
I
.
R
B
I
I
R
B
B
dependant on the load R
U
sensor should use to drive a maximum current of 20
mA via passive isolators and loads, can be read from
the Y-axis.
Input voltage depending on the load at I
V
The graphic shows the input voltage of U
If you know your load, the lowest voltage, which the
.
U
25
20
15
10
5
E
/ V
0
U
200
V
= 2,5 V
400
B
600
considering the power loss
800
A
= 20 mA
1000
R /
B
E

Related parts for MCR-1CLP-1-1-00

MCR-1CLP-1-1-00 Summary of contents

Page 1

... Current signals 0(4)...20 mA • 1-, 2- and 4-channel versions Description MCR-1,2,4CLP-I/I-00 passive isolators are used for the electrical isolation and processing of analog 0(4)… standard current signals. The blocks provide electrical isolation between the control electronics and process I/O. In addition, interference signals above 75 Hz are effectively suppressed ...

Page 2

... Multi-Channel Passive Isolator – MCR-...CLP-I/I-00 2. Technical Data IN OUT 1 (+) 0-20mA 2 (–) GND M 3 solid flexible 2 [mm ] AWG Connection data 0.2-2.5 0.2-2.5 24-14 Description MCR passive isolator , for electrical isolation of current 1-channel signals without power supply Technical Data Per Channel Input Input signal ...

Page 3

... Multi-Channel Passive Isolator – MCR-...CLP-I/I-00 IN OUT 1 (+) 0-20mA 2 (–) GND 3 (+) 0-20mA 4 (–) GND M 3 solid flexible 2 [mm ] AWG Connection data 0.2-2.5 0.2-2.5 24-14 Description MCR passive isolator , for electrical isolation of current signals without power supply Technical Data per Channel Input Input signal ...

Page 4

... Multi-Channel Passive Isolator – MCR-...CLP-I/I-00 IN OUT 1 (+) 0-20mA 2 (–) GND 3 (+) 0-20mA 4 (–) GND 5 (+) 0-20mA 6 (–) GND 7 (+) 0-20mA 8 (–) GND M 3 solid flexible 2 [mm ] AWG Connection data 0.2-2.5 0.2-2.5 24-14 Description MCR passive isolator , for electrical isolation of current signals without power supply ...

Page 5

... Multi-Channel Passive Isolator – MCR-...CLP-I/I- Conforms to the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC EMC (Electromagnetic Compatibility) Noise immunity in accordance with EN 50082-2 • Electrostatic discharge (ESD) • Electromagnetic HF field Amplitude modulation Pulsed modulation • Fast transients (burst) • Surge current load (surge) • ...

Page 6

... Multi-Channel Passive Isolator – MCR-...CLP-I/I-00 4. Application Example: Flow Rate Measurement Magnetic inductive flow meter 24V 0...20mA M CR- 1CLP- I/ OUT 2 6 GND 1 GND 2 PHOENIX CONTACT page 0...20mA Control system ...

Related keywords