P3-100/I5/SVB+K-CI MOELLER, P3-100/I5/SVB+K-CI Datasheet

ISOLATOR, PLASTIC, ENCL, 100A, 3POLE

P3-100/I5/SVB+K-CI

Manufacturer Part Number
P3-100/I5/SVB+K-CI
Description
ISOLATOR, PLASTIC, ENCL, 100A, 3POLE
Manufacturer
MOELLER
Series
P3r
Datasheet

Specifications of P3-100/I5/SVB+K-CI

No. Of Poles
3
Contact Voltage Ac Max
690V
Contact Current Ac Max
100A
Svhc
No SVHC (18-Jun-2010)
Current Rating
100A
Power Rating
50kW
Switching Ac3 Power Max
50kW
Voltage
RoHS Compliant
Type: P3−100/I5/SVB
Article No.: 207373
Contact sequence
1
Ordering information
Design
Description
Main conducting paths No. of poles
Auxiliary contacts
Auxiliary contacts
Max. three−phase motor rating (per set
of 3 contacts) 50−60 Hz AC−3 400/415
V 50−60 Hz
Rated uninterrupted current
Note for table header
General
Standards
Lifespan, mechanical
Operations
P
I
u
N/O
kW
M
B
A
× 10
6
Surface mounting
Without auxiliary contacts
3
0
0
50
100
According to IEC/EN 60204−1,
VDE 0113 Part 1; with red
rotary handle and yellow
locking collar, lockable in 0
position
IEC/EN 60947, VDE 0660,
IEC/EN 60204, CSA,UL
Switch−disconnectors to
IEC/EN 60947−3
0,1

Related parts for P3-100/I5/SVB+K-CI

P3-100/I5/SVB+K-CI Summary of contents

Page 1

... Type: P3−100/I5/SVB Article No.: 207373 Ordering information Design Description Main conducting paths No. of poles Auxiliary contacts Auxiliary contacts Max. three−phase motor rating (per set of 3 contacts) 50−60 Hz AC−3 400/415 V 50−60 Hz Rated uninterrupted current Note for table header Contact sequence ...

Page 2

Maximum operating frequency Climatic proofing Ambient temperature Open Enclosed Mounting position Documentation Mechanical shock resistance (shock duration 20 ms) Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current open Enclosed Load−carrying capacity in intermittent operation, ...

Page 3

Rated breaking capacity, motor load switch cos = 0.35 230 V 400 V 500 V 690 V Rated operational current 440 V load−break switch AC−21A AC−3 motor load switch motor rating 230 V 400 V 500 V 690 V AC−23A ...

Page 4

Notes Dimensions Explaination Dimensions 4 Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft The rated uninterrupted current I is stated at max. u connected cross−section. For terminal capacity solid, stranded and flexible: ...

Page 5

Dimensions Characteristic curve 5 ...

Page 6

... Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2006 by Moeller GmbH. Subject to modifications. HPL−C2006GB−INT V2.3 6 ...

Related keywords