CUB4L820 Red Lion Controls, CUB4L820 Datasheet - Page 3

no-image

CUB4L820

Manufacturer Part Number
CUB4L820
Description
Multifunction Counter
Manufacturer
Red Lion Controls
Datasheet

Specifications of CUB4L820

No. Of Digits / Alpha
8
Backlighting Color
Red
Panel Cutout Height
1.3"
Display Mode
LCD Negative Image Transmissive
Meter Signal Input
Pulse
Character Size
0.46"
Panel Cutout Width
2.68"
Ip/nema Rating
IP65 / NEMA 4X
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
WIRING CONNECTIONS
on the back of the unit. When wiring the unit, use the label to identify the wire
position with the proper function. All conductors should meet voltage and
current ratings for each terminal. Also cabling should conform to appropriate
standards of good installation, local codes and regulations. It is recommended
that power supplied to the unit (AC or DC) be protected by a fuse or circuit
breaker. Strip the wire, leaving approximately 1/4" bare wire exposed (stranded
wires should be tinned with solder). Insert the wire into the screw-clamp
terminal and tighten down the screw until the wire is clamped tightly. Each
terminal can accept up to two #14 AWG wires.
Note: The Reflective CUB4 will NOT have a screw terminal installed at the V+
Backlight Wiring
power supply. The external supply is connected between the V+ and Common
terminals.
CUB4L AND CUB4L8 LOW SPEED COUNT INPUT, 30 Hz MAX.
CUB4L8W L.S. INPUT, 30 CPS MAX.
accepts AC (50/60 Hz) or DC control voltages from 10 to 300 V at count speeds
up to 30 cps. The unit counts on the positive going edge of the input signal.
CUB4L HIGH SPEED COUNT INPUT, 5 KHz MAX.
The electrical connections are made via rear screw-clamp terminals located
terminal, since it is NOT required for operation and is not internally
connected. Refer to the Ordering Information for the part number of a
reflective model that will accommodate the MLPS.
Optional backlight versions of the CUB4 require an external 9-28 VDC
The CUB4L8W accepts most machine control voltage signals. The input
WARNING: Any lead may be at hazardous live input potential.
External wiring and devices connected to the unit must be rated
the same as applied signal input voltage and be properly
isolated from Class 2 or SELV circuitry.
with a mechanical or solid-state switch
increments the counter. The low pass filter used
with a Schmidt trigger circuit debounces
mechanical switch signals. The switch load is
14 µA (max. voltage drop 0.5 V) when ON. The
OFF-state leakage current must be less than 2
µA. Motor starter contacts, tungsten contacts,
and brush-type contacts should NOT be used.
Counter to operate at speeds up to 5 KHz
when driven by bi-polar outputs. Input drive
voltage must be limited to 28.0 V maximum
to avoid damage to the counter.
Pulling the “L.S. CNT.” Input to Common
INPUT PULSE EXCURSION LIMITS
The “H.S. CNT.” Input allows the CUB
V
IH
(High) = +4.0 V min., +28.0 V max.
V
IL
(Low) = +0.5 V max.
3
Note: This drawing is for CUB4L and CUB4L8 reference only.
For reference of CUB4L8W, refer to Backlight Option on page 4.
Warning: Lithium battery may explode if incinerated.
Caution: All leads will be at the same line potential as the input leads.