D4NS-5AF Omron, D4NS-5AF Datasheet - Page 8

SAFETY DOOR SWITCH

D4NS-5AF

Manufacturer Part Number
D4NS-5AF
Description
SAFETY DOOR SWITCH
Manufacturer
Omron
Datasheet

Specifications of D4NS-5AF

Contact Voltage Ac Max
400V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Switch Terminals
Screw
Svhc
Hexabromocyclododecane (HBCDD) And All Major Diastereoisomers Identified (15-Dec-2010)
Lead Free Status / RoHS Status
Safety Precautions
Refer to OMRON SAFETY COMPONENTS SERIES (Y106) for
common precautions.
Do not dismount the operation key from the door intentionally and
insert it to the switch with the door open. Machine may start
operating and injury or death may be caused.
Do not use metal connector or conduit with this switch. The broken
conduit hole may cause electrical shock hazard.
• Be careful not to drop your D4NS, or the switch will not fully exhibit
• Do not disassemble or remodel your D4NS in any case, or the
• Do not use the switch where explosive gas, ignitable gas, or any
• Install operation key so that it will not hit the operator when the door
• Do not use the switch in the oil and in the water. IP67(EN60947-5-1)
• Though the switch body is protected from the ingress of dust or
• Do not put the electric power when wiring.
• Be sure to install a cover after the wiring.
• Connect the fuse to the switch in series to prevent it from short
• Keep the electrical load below the rated value.
• On the switching of general loads (250VAC/3A), do not operate two
• The durability of the switch is seriously affected by operating
• Please mention in machine manufacturer's Instruction. Manual that
• Do not use the switch as a stopper.
1. Environment
• The switch is intended for indoor use only.
• Do not use your D4NS outdoor, or the switch will malfunction.
• Do not use your D4NS in the atmosphere of hazardous gases
• Do not use the switch under any of the conditions mentioned below.
8
its ability.
D4NS will not operate normally.
other harmful gasses may be present.
is open. Injury may be caused.
water, avoid the ingress of foreign substance through the key hole
on the head.
Otherwise, wear in short time or break may be caused
Do not put the electric power when opening a cover.
circuit damage.
The value of the breaking current of the fuse must be increased to
cover the rated current by 150 to 200%. When using the switch with
EN rating, use 10 A fuse, type gI or gG that complies with IEC
60269.
circuits or more at the same time. Otherwise, insulation
performance may be degraded.
conditions.
Evaluate the switch under actual working conditions before
permanent installation.
the user must not repair nor maintain the switch and must contact
machine manufacturer for them.
Be sure to install a stopper as shown in the following illustration to
prevent the edge of the operation key from inadvertently hitting the
switch directly.
(H2S, SO2, NH3, HNO3, CI2, etc.) or high temperature and
humidity, or it will cause the imperfect closing of the contacts or the
breakage thereof stemming from corrosion.
• Frequent temperature range.
Precautions for Safe Use
Precautions for Correct Use
Safety-door Switch
Operation Key
CAUTION
Switch
Stopper
D4NS
2. Mounting method
• Mounting Screw Tightening Torque
• Switch, operation key
3. Head direction
4. Securing of the door
Terminal screw
Cover clamping screw
Head clamping screw
Operation Key clamping screw (See item 4)
Body clamping screw (See item 4)
Conduit mounting connection (see item 10,11),
M12 changing adaptor
Cap screw
Loose mounting may result in malfunction.
Fasten the screws to the specified torque.
• High humidity or dew condensation may be generated.
• Where the switch is subject to severe vibration.
• Where the metal dust, oil, or chemical is sprayed inside the
• Where thinner is applied.
• The switch and operation key will be fastened to specified
• Secured more by the studs like below picture 4-0.05/-0.15 dia.,
• Do not use the operation key other than dedicated OMRON's.
• Be sure that the operation key can be inserted properly to key
The rotation of the switch head may be adjusted to any of the four
directions by loosening the head clamping screws at the four
corners of the head.
If the operation key is pulled in the opening direction due to a
force caused by vibration, by the door weight, or by a cushion
attached to the door.
The closed door must be secured with a hook or by similar
means.
door.
torque in item 2 with M4 screws and washers.
4.8 max. height at the lower two which are inserted from back
side of switch.
Otherwise switch may be damaged.
hole with a tolerance of ± 1 mm.
(Switch mounting holes)
2.5
5.35
47
(1 conduit type)
0.1
(2 conduits type)
0.1
2.5
39
0.1
0.1
Two, M4
20
22
22
Two, M4
0.1
0.1
0.1
Set zone
(0.5 to 3 mm)
4
4.8 max.
0.05
0.15
20
22
40
42
42
0.1
0.1
0.1
0.1
0.1
dia. height,
(Operation key mounting hole)
4
4.8 max.
D4DS-K1/-K2
0.05
0.15
D4DS-K3
D4DS-K5
Operation Key
dia. height,
15
41
0.1
0.1
40
or, 43
0.1
Two, M4
0.1
0.6 to 0.8 N·m
0.5 to 0.7 N·m
0.5 to 0.6 N·m
2.4 to 2.8 N·m
0.5 to 0.7 N·m
1.8 to 2.2 N·m
1.4 to 1.8 N·m (1/2-14NPT)
1.3 to 1.7 N·m
Two, M4
Two, M4

Related parts for D4NS-5AF