NEA0161501B0C Murata Power Solutions Inc, NEA0161501B0C Datasheet - Page 3

DC/DC TH 16A 8.3-14V-vari +ve

NEA0161501B0C

Manufacturer Part Number
NEA0161501B0C
Description
DC/DC TH 16A 8.3-14V-vari +ve
Manufacturer
Murata Power Solutions Inc
Series
NEA016r
Datasheet

Specifications of NEA0161501B0C

Output Power
240 W
Input Voltage Range
8.3 V to 14 V
Input Voltage (nominal)
12 V
Number Of Outputs
1
Output Voltage (channel 1)
15 V
Output Current (channel 1)
16 A
Package / Case Size
SIP
Output Type
Adjustable
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Volant NEA016 Series
Murata Power Solutions
Non-Isolated 16A SIP/SMT DC/DC Converters
Standards Compliance
CSA C22.2, No.60950/UL 60950, Third Edition (2000), File UL E165113
Thermal Considerations
The power module operates in a variety of thermal environments; however, sufficient cooling should
be provided to help ensure reliable operation of the unit.
The thermal data presented is based on measurements taken at various airflows. Note that airflow is
parallel to the long axis of the module as shown in Figure 1 and derating applies accordingly.
Figure 1. Thermal Tests Set-Up.
NOT RECOMMENDED
The temperature at either location should not exceed 110°C. The output power of the module should
FOR NEW DESIGNS
not exceed the rated power for the module(Vo,set X Io,max).
Convection Requirements for Cooling
To predict the approximate cooling needed for the module, refer to the Power Derating Curves in
Figures 2-17 .
These derating curve are approximations of the ambient temperature and airflow required to keep the
power module temperature below it's maximum rating. Once the module is assembled in the actual
system, the module's temperature should be verified.
3
NEA016_6200860000_B01_21/04/08

Related parts for NEA0161501B0C