IQ48240HPC10NRS-G SYNQOR, IQ48240HPC10NRS-G Datasheet - Page 26

InQor DC/DC Converters

IQ48240HPC10NRS-G

Manufacturer Part Number
IQ48240HPC10NRS-G
Description
InQor DC/DC Converters
Manufacturer
SYNQOR
Datasheet

Specifications of IQ48240HPC10NRS-G

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
34V To 75V
Power Rating
252W
Output Voltage
24V
Output Current
10.5A
Approval Bodies
UL, CUL, TUV, IEC
Supply Voltage
48V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Product # IQ48xxxHPXxxx
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.
Standards & Qualification Testing
Parameter
STANDARDS COMPLIANCE
UL 60950-1: 2003
CAN/CSA-C22.2 No. 60950-1:2003
EN60950-1:2001
IEC 61000-4-2
Parameter
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
Altitude
Phone 1-888-567-9596
# Units Test Conditions
Notes & Conditions
Basic Insulation
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
15 pins
32
10
5
5
5
5
5
2
www.synqor.com
95% rated Vin and load, units at derating point, 1000 hours
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x, y, and z axis
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
MIL-STD-883, method 2003
70,000 feet (21 km), see Note
Doc.# 005-0005244 Rev. C
IQ48xxxHPXxxx
Specification
07/12/10
Technical
Page 26