NQ40W40QGC30NNS-G SYNQOR, NQ40W40QGC30NNS-G Datasheet

NiQor DC/DC Converters

NQ40W40QGC30NNS-G

Manufacturer Part Number
NQ40W40QGC30NNS-G
Description
NiQor DC/DC Converters
Manufacturer
SYNQOR
Datasheet

Specifications of NQ40W40QGC30NNS-G

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
9V To 40V
Output Voltage
40V
Output Current
30A
Approval Bodies
UL, CUL, TUV, IEC
Dc / Dc Converter Case Style
Quarter Brick
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Product # NQ40x40QGx30
The NiQor quarter-brick dc-dc converter is a non-isolated
buck-boost regulator, which employs synchronous rectification
to achieve extremely high conversion efficiency. The High
Input Voltage NiQor Brick family of converters can be used
in traditional DPA (distributed power architecture) systems
or provide a regulated output voltage from a battery source
or other variable voltage source. The NiQor quarter-brick
family can be configured to Buck the input voltage down to
a lower voltage or Boost the input voltage up to a higher
voltage using a single external resistor. These modules are
RoHS 6/6 compliant (see page 10).
• Industry standard quarter-brick pin-out configuration
• Sizes: Encased - 1.54" x 2.39" (39x60.6 mm)
• Total height: Encased - 0.515" (13.08 mm)
• Total weight: Encased - 3 oz (85 g)
• Ultra high efficiency, up to 95% at full rated load
• Delivers up to 30 A of output current
• Input Voltage Range: 9 - 40 V
• Output voltage range: 0 - 40 V (negative output is possible)
• Extensive on-board input and output filtering
• No minimum load requirement means no preload resistors
• Buck or buck-boost mode available
• Adjustable current limit with current monitor (C option)
• On/Off control
• Output voltage trim permits custom voltages
• Remote Sense (S option, standard)
• Current limit trim (C option)
Continuous Input
required
Operational Features
Control Features
Mechanical Features
9-40V
Flanged - 2.20" x 2.39" (55.88x60.6 mm)
Flanged - 0.500" (12.7mm)
Flanged - 3.17oz (90g)
Phone 1-888-567-9596
0-40V
Outputs
www.synqor.com
Current
30A
• Input under-voltage lockout protects the converter at low
• Over-current shutdown protects converter from excessive
• Input/output over-voltage protection protects load
• Thermal shutdown protects converter from abnormal envi-
Mechanical Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
input voltage conditions
load current or short circuits
and regulator from damaging voltages
ronmental conditions
Contents
Protection Features
Safety Features
UL 60950-1:2003
EN60950-1:2001
IEC 61000-4-2
Doc.# 005-NQ4040W Rev. E
NiQor quarter-brick module
Isolated
Non-
NQ40x40QGx30
Specification
Non-Isolated
Technical
Quarter-brick
06/30/10
DC-DC Converter
Page No.
Page 1

Related parts for NQ40W40QGC30NNS-G

NQ40W40QGC30NNS-G Summary of contents

Page 1

... Thermal shutdown protects converter from abnormal envi- ronmental conditions Safety Features UL 60950-1:2003 ● EN60950-1:2001 ● IEC 61000-4-2 ● Contents Mechanical Diagram Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 www.synqor.com Doc.# 005-NQ4040W Rev. E Technical Specification NQ40x40QGx30 Quarter-brick DC-DC Converter Non-Isolated Page No. 06/30/10 Page 1 ...

Page 2

... TRIM SENSE 7 (+) 8 Vout(+) Notes: 1)SENSE(–) should be connected to Vout(–) either remotely or at the converter 2)SENSE(+) should be connected to Vout(+) either remotely or at the converter. www.synqor.com Doc.# 005-NQ4040W Rev Input Outputs Current: Quarter-brick Package: .515±.025 [13.08± 0.63] OVERALL HEIGHT Side View ...

Page 3

... Pin Notes: 1)SENSE(–) should be connected to Vout(–) either remotely or at 2)SENSE(+) should be connected to Vout(+) either remotely or at www.synqor.com Input Outputs Current: Quarter-brick Package: .18 [4,6 ] SEE NOTE 5 & 2.00 [50,8 ] 2.386 .020 [60,6 ...

Page 4

... Doc.# 005-NQ4040W Rev Input Outputs Current: Quarter-brick Package: Continuous Continuous Turn on at 10V Fast blow external fuse recommended Input current max equals output rated current ESR < 1.5 Ω Output voltage dependent Set output by Rtrim resistor Sense pin, over sample, line, load, temp. & life 24 Vin Full Load ...

Page 5

... UL 60950-1:2003 CAN/CSA-C22.2 No. 60950-1:2003 EN60950-1:2001 Needle Flame Test (IEC 695-2-2) IEC 61000-4-2 Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. Parameter QUALIFICATION TESTING Life Test Vibration ...

Page 6

... Terminal Ripple Current (Figure 5), and Output Voltage Ripple (Figure 6). 36 Vout 24 Vout 12 Vout Figure 6: Output Voltage Ripple with 24 V input and rated load F electrolytic cap. µ current (50 mV/div). Load capacitance: 100 Bandwidth: 20 MHz. See Figure 4. www.synqor.com Doc.# 005-NQ4040W Rev Input Outputs Current: Quarter-brick ...

Page 7

... Ch 2-4: Vout (10 V/div) 3.0 2.5 2.0 1.5 1.0 0.5 0 Figure 10: Current limit vs. Itrim pin voltage with 24 V input and 13.8 V output. Load capacitance: 100 36 Vout 24 Vout 12 Vout www.synqor.com Doc.# 005-NQ4040W Rev Input Outputs Current: Quarter-brick Package: 34 Vout 18 Vout 12 Vout on/off Current Limit (A) F electrolytic cap. C option only. µ ...

Page 8

... The thermal shutdown circuit is designed to turn the converter ( Ω ) off when the temperature at the sensed location reaches the max Over-Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value. www.synqor.com Input Outputs Current: Quarter-brick ...

Page 9

... Figure C: Current monitor/trimmable current limit setup The R trim-up function to the S option The R in adjItrim to the following equation: V out R adjItrim Alternatively, the I source The I mon figure 9. This pin has a 10kOhm output impedance. www.synqor.com Input Outputs Current: Quarter-brick Package: Cin2 1 8 Vout+ Vin+ 7 SENSE ENABLE TRIM ...

Page 10

... Not all combinations make valid part numbers, please contact SynQor for availability. See the Product Summary web page for more options. PATENTS SynQor holds the following U.S. patents, one or more of which apply to each product listed in this brochure. Additional patent applications may be pending or filed in the future. ...

Related keywords