TEP 100-1216 TRACOPOWER, TEP 100-1216 Datasheet - Page 3

DC/DC CONVERTER, 28V, 100W

TEP 100-1216

Manufacturer Part Number
TEP 100-1216
Description
DC/DC CONVERTER, 28V, 100W
Manufacturer
TRACOPOWER
Datasheet

Specifications of TEP 100-1216

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
9V To 18V
Power Rating
100W
Output Voltage
28V
Output Current
3.6A
Approval Bodies
CURus
Supply Voltage
12V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Output Specifications
Start up time (nominal Vin and constant resistive load)
Transient response (25% load step change)
Output current limitation
Over voltage protection
Short circuit protection
Capacitive load
General Specifications
Temperature ranges
Thermal impedance
Derating
Over temperature protection
Thermal shock
Humidity (non condensing)
Reliability, calculated MTTF (MIL-HDBK-217F, @ +25°C, ground benign)
Isolation voltage (60sec.)
Isolation capacitance
Isolation resistance
Switching frequency
Safety standards
Safety approvals
Remote On/Off
Environmental compliance
Application note:
www.tracopower.com/products/tep100-application.pdf
– Operating
– Case temperature
– Storage
– without Heatsink
– with Heatsink
– Input/Output
– Input/Case
– Input/Output
– Input/Output (500 VDC)
– UL/cUL
– positive logic (standard)
– negative logic (option -N)
– Off idle current:
– Reach
– RoHS
3.3 & 5 VDC models: 40‘000 µF max.
48 VDC models: 430 µF max.
24 VDC models: 1‘750 µF max.
28 VDC models: 1‘280 µF max.
12 VDC models: 7‘000 µF max.
15 VDC models: 4‘460 µF max.
– On: 3 to 12 VDC or open circuit
– Off: 0 to 1.2 VDC or short circuit pin 1 and 3
– On: 0 to 1.2 VDC or short circuit pin 1 and 3
– Off: 3 to 12 VDC or open circuit
25 ms typ. (at power On or remote On)
200 µs typ.
at 110 -140 % of Iout max.
at 115 -130 % of Vout nom.
indefinite, automatic recovery
–40°C to +75°C
+105°C max.
–55°C to +125°C
6.7°C/W
4.7°C/W
See derating graphs page 4
at 115°C
acc. MIL-STD-810F
95 % rel H max.
75‘000 h
2’250 VDC (basic insulation)
1’500 VDC
2500 pF max.
>1 GOhm min.
300 kHz typ. (puls width modulation)
UL 60950-1 , IEC/EN 60950-1
www.ul.com
3 mA
www.tracopower.com/products/tep100-reach.pdf
RoHS directive 2002/95/EC
DC/DC Converters
TEP 100 Series
-> certifications -> File E188913
100 Watt
Page 3 of 6

Related parts for TEP 100-1216