BXB100-48S12FLTJ Emerson Network Power, BXB100-48S12FLTJ Datasheet

DC/DC Converter

BXB100-48S12FLTJ

Manufacturer Part Number
BXB100-48S12FLTJ
Description
DC/DC Converter
Manufacturer
Emerson Network Power
Datasheet

Specifications of BXB100-48S12FLTJ

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
36V To 75V
Power Rating
100W
Output Voltage
12V
Output Current
8.3A
Approval Bodies
UL, CSA, VDE
Supply Voltage
48V
Output Power
100 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
8.33 A
Package / Case Size
2.28 in x 2.4 in x 0.5 in
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
BXB100 Series
Single output
Special Features
• Industry standard footprint
• High power density
• MTBF >1.4 million hours
• Input voltage to ETS300-132-2
• Adjustable output voltage
• No minimum load required
• Separate case ground pin
• Undervoltage lockout (UVLO)
• UL, VDE and CSA safety
• 2 year warranty
Safety
VDE0805/EN60950/IEC950
UL1950
CSA C22.2 No. 950
Total Power:
Input Voltage: 18 - 36 V
# of Outputs:
(36.5 W/in3)
(Bellcore 332)
approvals
66 - 100 W
36 - 75 V
Single
Electrical Specifications
Input
Input voltage range:
Input current:
Input current (max.):
(See note 4)
Input reflected ripple:
Active low remote ON/OFF:
Logic compatiblity:
ON:
OFF:
Undervoltage lockout:
Start-up time:
(see note 8)
Output
Voltage adjustability:
Setpoint accuracy:
Line regulation:
Load regulation:
Minimum load:
Overshoot:
Undershoot:
Ripple and noise:
5 Hz - 20 MHz (see note 1)
Low line to high line
Full load to min. load
At turn on and turn-off
3.3 V and 5 V
12V and 15 V
24 Vin nominal
48 Vin nominal
No load
Remote OFF
48 V models
(See note 6)
24 Vin: power-up
24 Vin: power-down
48 Vin: power-up
48 Vin: power-down
Power up
Remote ON/OFF
Open collector ref to -input
Open circuit
1.2 Vdc max.
Embedded Power for
Business-Critical Continuity
and Vin = 0 to 75 V
4 A max. @ lo max.
100 mV pk-pk,
Rev.10.16.08_121
100 mA max.
75 mV pk-pk,
60% to 110%
20 mA max.
(See note 7)
5 mA pk-pk
18 - 36 Vdc
36 - 75 Vdc
BXB100 Series
20 mV rms
30 mV rms
±0.05%
±0.10%
32.5 V
20 ms
20 ms
±1.0%
None
None
17 V
16 V
34 V
1 of 3
0 %

Related parts for BXB100-48S12FLTJ

BXB100-48S12FLTJ Summary of contents

Page 1

... Open circuit 24 Vin: power-up 24 Vin: power-down 48 Vin: power-up 48 Vin: power-down Power up Remote ON/OFF 60% to 110% Low line to high line Full load to min. load At turn on and turn-off 3.3 V and pk-pk, 12V and 15 V 100 mV pk-pk, BXB100 Series Vdc Vdc 5 mA pk- 32 ±1.0% ±0.05% ±0.10 None None 20 mV rms 30 mV rms ...

Page 2

... VDE0805, EN60950, IEC950 UL1950, CSA C22.2 No. 950 Aluminum baseplate with plastic case UL94V-0 110 g (3.88 oz) 1,400,000 hours 580,000 hours min. Continuous, automatic recovery Non-latching Non-latching 110 °C baseplate, automatic recovery -40 ºC to +100 ºC -55 ºC to +125 ºC 10,000 feet max. 40,000 feet max. 2.4 G rms (approx.) Embedded Power for Business-Critical Continuity Rev.10.16.08_121 BXB100 Series ...

Page 3

... Embedded Power for Business-Critical Continuity Americas 5810 Van Allen Way Carlsbad, CA 92008 USA Model Number Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 BXB100-24S12FLTJ BXB100-48S05FLTJ Europe (UK) Waterfront Business Park BXB100-48S12FLTJ Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 8 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon RT1 7 Hong Kong ...

Related keywords