UEI-3.3/15-Q12NR-C Murata Power Solutions Inc, UEI-3.3/15-Q12NR-C Datasheet - Page 6

CONVERTER, DC/DC, 3.3V, 15A

UEI-3.3/15-Q12NR-C

Manufacturer Part Number
UEI-3.3/15-Q12NR-C
Description
CONVERTER, DC/DC, 3.3V, 15A
Manufacturer
Murata Power Solutions Inc

Specifications of UEI-3.3/15-Q12NR-C

No. Of Output Channels
1
Input Voltage
9V To 36V
Power Rating
49.5W
Output Voltage
3.3V
Output Current
15A
Supply Voltage
24V
Dc / Dc Converter Case Style
Through Hole
Isolation Voltage
2.25kV
Product
Isolated
Output Power
50 W
Input Voltage Range
9 V to 36 V
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
15 A
No. Of Outputs
1
Approval Bodies
CSA / EN / UL
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Absolute Maximum Ratings
Absolute maximums are stress ratings. Exposure of devices to any of these
conditions may adversely affect long-term reliability. Proper operation under
conditions other than those listed in the Performance/Functional Specifications
is neither implied nor recommended.
Input Fusing
Certain applications and/or safety agencies may require fuses at the inputs of
power conversion components. Fuses should also be used when there is the
possibility of sustained input voltage reversal which is not current-limited. We
recommend a time delay fuse installed in the ungrounded input supply line
with a value which is approximately twice the maximum line current, calcu-
lated at the lowest input voltage.
safety agency approvals, install the converter in compliance with the end-user
safety standard, i.e. IEC/EN/UL 60950-1.
Input Reverse-Polarity Protection
If the input voltage polarity is reversed, an internal diode will become forward
biased and likely draw excessive current from the power source. If this source
is not current-limited or the circuit appropriately fused, it could cause perma-
nent damage to the converter.
Input Under-Voltage Shutdown and Start-Up Threshold
Under normal start-up conditions, converters will not begin to regulate properly
until the ramping-up input voltage exceeds and remains at the Start-Up
Threshold Voltage (see Specifications). Once operating, converters will not
turn off until the input voltage drops below the Under-Voltage Shutdown Limit.
Subsequent restart will not occur until the input voltage rises again above the
Start-Up Threshold. This built-in hysteresis prevents any unstable on/off opera-
tion at a single input voltage.
Shutdown whose voltage decays as input current is consumed (such as capaci-
tor inputs), the converter shuts off and then restarts as the external capacitor
recharges. Such situations could oscillate. To prevent this, make sure the operat-
ing input voltage is well above the UV Shutdown voltage AT ALL TIMES.
ABSOLUTE MAXIMUM RATINGS
Input Voltage
On/Off control, referred to –V
Input Reverse Polarity Protection
Output Overvoltage, Volts Max.
Output Current, sustained short circuit
Storage Temperature
Lead Temperature ºC Max. (soldering, 10 seconds)
The installer must observe all relevant safety standards and regulations. For
Users should be aware however of input sources near the Under-Voltage
Q12 models
Q48 models
in
APPLICATION NOTES
Volts, transient 100mS
Volts, transient 100mS
Volts Max. continuous
Volts Max. continuous
Range, Min. ºC
Volts, Max.
Volts, Min.
Max. ºC
www.murata-ps.com
V
See fuse section
Current-limited,
out
see specs
nom. +20%
+125
-0.3
100
–55
280
36
50
75
15
Start-Up Time
Assuming that the output current is set at the rated maximum, the Vin to Vout Start-
Up Time (see Specifications) is the time interval between the point when the ramping
input voltage crosses the Start-Up Threshold and the fully loaded regulated output
voltage enters and remains within its specified accuracy band. Actual measured
times will vary with input source impedance, external input capacitance, input volt-
age slew rate and final value of the input voltage as it appears at the converter.
PWM controller at power up, thereby limiting the input inrush current.
assumes that the converter already has its input voltage stabilized above the
Start-Up Threshold before the On command. The interval is measured from the
On command until the output enters and remains within its specified accuracy
band. The specification assumes that the output is fully loaded at maximum
rated current. Similar conditions apply to the On to V
such as external load capacitance and soft start circuitry.
Input Source Impedance
These converters will operate to specifications without external components,
assuming that the source voltage has very low impedance and reasonable
input voltage regulation. Since real-world voltage sources have finite imped-
ance, performance is improved by adding external filter components. Some-
times only a small ceramic capacitor is sufficient. Since it is difficult to totally
characterize all applications, some experimentation may be needed. Note that
external input capacitors must accept high speed switching currents.
converters must be driven from a source with both low AC impedance and
adequate DC input regulation. Performance will degrade with increasing input
inductance. Excessive input inductance may inhibit operation. The DC input
regulation specifies that the input voltage, once operating, must never degrade
below the Shut-Down Threshold under all load conditions. Be sure to use
adequate trace sizes and mount components close to the converter.
I/O Filtering, Input Ripple Current and Output Noise
All models in this converter series are tested and specified for input reflected
ripple current and output noise using designated external input/output compo-
nents, circuits and layout as shown in the figures below. External input capaci-
tors (C
line voltage variations caused by transient IR drops in the input conductors.
Users should select input capacitors for bulk capacitance (at appropriate
frequencies), low ESR and high RMS ripple current ratings. In the figure below,
These converters include a soft start circuit to moderate the duty cycle of its
The On/Off Remote Control interval from On command to V
Because of the switching nature of DC/DC converters, the input of these
V
in
IN
OSCILLOSCOPE
in the figure) serve primarily as energy storage elements, minimizing
50-60W Isolated Wide-Range DC/DC Converters
C
C
L
+
+
BUS
IN
BUS
TO
= 33µF, ESR < 700mΩ @ 100kHz
= 12µH
= 220µF, ESR < 100mΩ @ 100kHz
Technical enquiries email: sales@murata-ps.com, tel:
Figure 2. Measuring Input Ripple Current
C
BUS
L
BUS
MDC_UEI Series 50-60W.B16 Page 6 of 10
CURRENT
PROBE
C
IN
1
2
out
UEI Series
regulated specification
+INPUT
−INPUT
out
+1 508 339 3000
regulated

Related parts for UEI-3.3/15-Q12NR-C