Specifications of BXA30-48D05-FJ

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
2
Input Voltage
36V To 75V
Power Rating
30W
Output Voltage
5V
Output Current
2.5A
Output Voltage 2
-5V
Output Current 2
-2.5A
Product
Isolated
Output Power
13 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
2
Output Voltage (channel 1)
5 V
Output Current (channel 1)
2.5 A
Output Voltage (channel 2)
5 V
Output Current (channel 2)
2.5 A
Isolation Voltage
1.5 KV
Package / Case Size
76.3 mm x 61 mm x 13.3 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
BXA30 Series
Single and dual output
Special Features
• Designed to meet telecom
• UL, VDE and CSA
• VDE0878 and EN55022
• EN61000-4-2, -3, -4, -5, -6
• Fixed frequency operation at
• MTBF in excess of 7,005,000
• Basic insulation system
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/IEC950
File No. 14501-3336-7006
Licence No. 6231
UL1950 File No. E174104
CSA C22.2 No. 950
File No. LR41062C
Total Power:
Input Voltage: 9 - 18VDC
# of Outputs:
power supply interface
standard ETS300-132-2
safety approvals
conducted emissions level A
immunity compliant
350 kHz
hours (demonstrated)
30W
36 - 75VDC
Single, dual
The BXA30 series, comprising 9 different models, has been
conceived as an applications-specific range of dc-dc converters,
specifically addressing telecommunications, industrial electronics,
test equipment, mobile telecommunications and distributed
power applications. The series offers three wide input voltage
ranges, 9 Vdc to 18 Vdc and 36 Vdc to 75 Vdc, and is available in
single and dual output versions. Designed to meet ETSI telecoms
interface standards ETS300-132-2 and BTR2511, together with
internal filtering to EN55022 level A, safety approval to EN60950
and UL1950, and isolation of 1500 Vdc, the 48 Vdc models are
ideal for telecommunications applications. The 12 V models are
particularly suited to industrial, mobile telecom and test
equipment applications, featuring EN61000-4-2, -3, -4, -5 and -6
immunity compliant. Other features include low output ripple,
overvoltage protection, continuous short circuit protection,
remote enable and remote sense.
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
1 of 5

Related parts for BXA30-48D05-FJ

BXA30-48D05-FJ Summary of contents

Page 1

... Licence No. 6231 UL1950 File No. E174104 CSA C22.2 No. 950 File No. LR41062C The BXA30 series, comprising 9 different models, has been conceived as an applications-specific range of dc-dc converters, specifically addressing telecommunications, industrial electronics, test equipment, mobile telecommunications and distributed power applications. The series offers three wide input voltage ranges, 9 Vdc to 18 Vdc and 36 Vdc to 75 Vdc, and is available in single and dual output versions ...

Page 2

... CSA C22.2 No. 950 Aluminum substrate with plastic case UL94V-0 120 g (4.24 oz) Demonstrated @ 25 °C 7,005,000 hours Baseplate operating -25 °C to +100 °C temperature, (See Notes 6, 8) Non-operating -55 °C to +100 °C Free air convection, 6.5 °C/W baseplate to air With heatsink (See Note 8) 5.2 °C/W Rev.12.17.07 bxa30 ...

Page 3

... VDE0878 level A and EN55022 level A. Add the suffix ‘-F’ to the model number, e.g. BXA30-48S12-FJ. See BXA15 and BXA30 Design Note 100. 5 For conducted noise operation of the BXA30 to VDE0871, VDE0878 and EN55022 level B, see BXA15 and BXA30 Design Note 100. 6 For extended operating temperature, include the heatsink option, ‘-1’ in the model number ...

Page 4

... Common – Vout No Pin No Pin Remote ON/OFF Embedded Power for Business-Critical Continuity 0.76 (19.200.30) 0.302 (7.670.30) 0.95 (24.13) 0.6 (15.24) 0.4 (10.16) 1.30 (33.02) 1.15 (29.21) 0.52 (13.300.30) SIDE VIEW 5 5 TRIM 10K TRIMPOT TRIM DOWN 3 3 Rev.12.17.07 bxa30 2.41 (61.100.30) ...

Page 5

... Embedded Power for Business-Critical Continuity Rev.12.17.07 bxa30 Americas 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 ...

Related keywords