IQ12050QTC20NRS-G SYNQOR, IQ12050QTC20NRS-G Datasheet - Page 3

InQor DC/DC Converters

IQ12050QTC20NRS-G

Manufacturer Part Number
IQ12050QTC20NRS-G
Description
InQor DC/DC Converters
Manufacturer
SYNQOR
Datasheet

Specifications of IQ12050QTC20NRS-G

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
9V To 22V
Power Rating
100W
Output Voltage
5V
Output Current
20A
Approval Bodies
UL, CUL, TUV, IEC
Supply Voltage
12V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Product # IQ12xxxQTCxx
IQ12 FaMIly eleCTRICal ChaRaCTeRISTICS (all output voltages)
T
temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
note 1: Higher values of isolation capacitance can be added external to the module.
TeMPeRaTURe lIMITS FOR POWeR DeRaTInG CURVeS
aBSOlUTe MaXIMUM RaTInGS
InPUT ChaRaCTeRISTICS
DynaMIC ChaRaCTeRISTICS
ISOlaTIOn ChaRaCTeRISTICS
FeaTURe ChaRaCTeRISTICS
RelIaBIlITy ChaRaCTeRISTICS
A
=
Input Voltage
Isolation Voltage
Operating Temperature
Storage Temperature
Voltage at ON/OFF input pin
Operating Input Voltage Range
Input Under-Voltage Lockout
Recommended External Input Capacitance
Turn-On Transient
Isolation Voltage (dielectric strength)
Isolation Resistance
Isolation Capacitance (input to output)
Semiconductor Junction Temperature
Board Temperature
Transformer Temperature
Maximum Baseplate Temperature, T
Switching Frequency
ON/OFF Control
ON/OFF Control
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
Calculated MTBF (Telcordia) TR-NWT-000332
Calculated MTBF (MIL-217) MIL-HDBK-217F
Field Demonstrated MTBF
25 °C, airflow rate = 300 LFM,
Non-Operating
Operating
Operating Transient Protection
Input to Output
Input to Base-Plate
Output to Base-Plate
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Turn-On Time
Start-Up Inhibit Time
Output Voltage Overshoot
Off-State Voltage
On-State Voltage
Pull-Up Voltage
Pull-Up Resistance
Phone 1-888-567-9596
V
B
IN
=
1
12
V
DC
unless
Min.
200
230
-40
-55
9.2
8.3
2.4
-2
-2
9
otherwise noted; full operating temperature range is -40 °C to +100 °C ambient
www.synqor.com
Typ.
1000
2.5
2.0
470
230
250
125
9.5
8.6
0.9
12
30
50
10
9
0
5
Max.
2250
2250
2250
100
125
125
125
125
100
270
250
9.8
8.9
0.8
30
22
25
18
22
18
Doc.# 005-IQ12QTX Rev. C
Units notes & Conditions
10
10
10
Vdc
Vdc
Vdc
MW
kHz
ms
ms
kW
°C
°C
µF
pF
°C
°C
°C
°C
°C
°C
6
6
6
%
V
V
V
V
V
V
V
V
V
V
V
Hrs 80% load, 300LFM, 40 °C T
Hrs 80% load, 300LFM, 40 °C T
Hrs See our website for details
Continuous
Continuous
100 ms transient, square wave
Basic insulation, Pollution Degree 2
Baseplate temperature
25 V transient for 100 ms
Typical ESR 0.1-0.2 W
Full load, V
See Figure F
Maximum Output Capacitance
See Absolute Maximum Ratings
Package rated to 150 °C
UL rated max operating temp 130 °C
See Common Figure 3 for derating curve
Regulation and Isolation stages
Common Figures A & B
Average PCB Temperature
IQ12-QTC Family
Specification
out
=90% nom.
Technical
09/23/08
A
A
Page 3

Related parts for IQ12050QTC20NRS-G