UHE-12/2500-Q48 Murata Power Solutions Inc, UHE-12/2500-Q48 Datasheet
UHE-12/2500-Q48
Specifications of UHE-12/2500-Q48
Available stocks
Related parts for UHE-12/2500-Q48
UHE-12/2500-Q48 Summary of contents
Page 1
... Selected models are RoHS compliant (Reduction of Hazardous Substances). +OUTPUT (6) +SENSE (5) –OUTPUT (7) –SENSE OPTO (8) ISOLATION OVERVOLTAGE COMPARATOR REFERENCE & OPTO ERROR AMP ISOLATION V TRIM OUT (9) models ("R" suffi x). OUT * One phase of two is shown. email: sales@murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page Trim function OUT ...
Page 2
... UHE-5/5000-Q48 UHE-5/6000-Q12 UHE-5/6000-D48 UHE-5/6000-D48T UHE-5/6000-Q48T UHE-12/2500-Q12-C 12 2.5 UHE-12/2500-D12-C 12 2.5 UHE-12/2500-D24-C 12 2.5 UHE-12/2500-Q48-C 12 2.5 UHE-12/2500-D48-C 12 2.5 UHE-15/2000-D12 UHE-15/2000-Q12 UHE-15/2000-D24 UHE-15/2000-Q48 UHE-15/2000-D48 Typical +25°C under nominal line voltage and full-load conditions, unless noted. A Ripple/Noise (R/N) is tested/specifi ed over a 20MHz bandwidth. All models are specifi ed with an external 0.47µ ...
Page 3
... Please contact Product Marketing for further information. Adaptations There are various additional confi gurations available on UHE, 12-30W DC/DCs. Because designating each of them with a standard part-number suffi not always feasible, such are designated by MPS in assigning a 5-digit “adaptation code” ...
Page 4
... UHE Series Isolated, High Effi ciency, 1.6" × 2" 2-10 Amp, 12-30 Watt DC/DC Converters PLASTIC CASE STANDOFF 0.020 (0.5) 0.10 (2.54) 0.200 (5.1) 1.60 0.400 (40.6) (10.2) 0.400 (10.16) 2 EQ. SP. @ 0.200 (5.08) 0.20 (5.1) email: sales@murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page ...
Page 5
... TBC million hours ➉ –40 to +85°C with Derating +115°C to +130°C –55 to +125° V-0 Physical 1.6" x 2" x 0.40" (40.64 x 50.8 x 10.16mm) Diallyl Phthalate Gold-plated copper alloy 1.51 ounces (46.9 grams) Basic email: sales@murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page ➇ ...
Page 6
... Amp, 12-30 Watt DC/DC Converters Typical Performance Curves www.murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page UHE Series Isolated, High Effi ciency, 1.6" × 2" email: sales@murata-ps.com ...
Page 7
... UHE-5/6000-Q12 Efficiency vs. Load @ + 24V 36V IN 65 0.49 0.99 1.49 1.99 www.murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page UHE Series Isolated, High Effi ciency, 1.6" × 2" C Ambient ° 12V IN 2.49 3.00 3.50 4.00 4.50 5.00 5.50 6.00 Output Current (Amps) email: sales@murata-ps.com ...
Page 8
... Amp, 12-30 Watt DC/DC Converters Typical Performance Curves www.murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page UHE Series Isolated, High Effi ciency, 1.6" × 2" email: sales@murata-ps.com ...
Page 9
... Amp, 12-30 Watt DC/DC Converters Typical Performance Curves www.murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page UHE Series Isolated, High Effi ciency, 1.6" × 2" email: sales@murata-ps.com ...
Page 10
... UHE-3.3/7500-Q48 Maximum Current Temperature Derating (V = 48V, airflow = 300 LFM 300 LFM UHE-5/5000-Q48 Maximum Current Temperature Derating (V = 48V, airflow = 300 LFM 300 LFM www.murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page UHE Series Isolated, High Effi ciency, 1.6" × 2" 100 Ambient Temperature ( 100 Ambient Temperature ( C) email: sales@murata-ps.com ...
Page 11
... Amp, 12-30 Watt DC/DC Converters Typical Performance Curves www.murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page UHE Series Isolated, High Effi ciency, 1.6" × 2" email: sales@murata-ps.com ...
Page 12
... I/O Filtering, Input Ripple Current, and Output Noise All models in the UHE 12-30 Watt DC/DC Converters are tested/specifi ed for in- put refl ected ripple current and output noise using the specifi ed external input/ output components/circuits and layout as shown in the following two fi gures. ...
Page 13
... If the short-circuit condition persists, another shutdown cycle will be initiated. This on/off cycling is referred to as “hiccup” mode. The hiccup cycling reduces the average output current, thereby preventing internal temperatures from rising to excessive levels. The UHE is capable of enduring an indefi nite short circuit output condition. www.murata-ps.com UHE Series Isolated, High Effi ...
Page 14
... Applying an external voltage to pin 4 when no input power is applied to the converter can cause permanent damage to the converter. Trimming Output Voltage UHE converters have a trim capability (pin 9) that allows users to adjust the output voltages ± (±10% for T models). Adjustments to the output OUT voltages can be accomplished via a trim pot (Figure single fi ...
Page 15
... Use of trim and sense functions can O cause output voltages to increase thereby increasing output power beyond the UHE’s specifi ed rating or cause output voltages to climb into the output 37.875 overvoltage region. Therefore, the designer must ensure: – ...
Page 16
... Specifi cations are subject to change without notice. www.murata-ps.com/locations UHE Series Isolated, High Effi ciency, 1.6" × 2" 2-10 Amp, 12-30 Watt DC/DC Converters © 2011 Murata Power Solutions, Inc. email: sales@murata-ps.com 28 Mar 2011 MDC_UHE_12-30W Series.B16 Page ...