1891321 FRIWO, 1891321 Datasheet - Page 10
![no-image](/images/no-image-200.jpg)
1891321
Manufacturer Part Number
1891321
Description
ADAPTOR, PP USB US, 5 V 700 MA
Manufacturer
FRIWO
Datasheet
1.1891321.pdf
(11 pages)
Specifications of 1891321
Power Supply Output Type
Fixed
Input Voltage
90VAC To 264VAC
Output Voltage
5V
Output Current
0.7A
Connector Type
USB Type A
Operating Temperature Max
45°C
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
8
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
www.friwo.de
Links & Miscellaneous
EMC-specification
Noise-suppressed: acc. to EN55024 ,55022/B and FCC part 15 B
Immunity to electrostatic discharge (ESD): acc. to EN 61000-4-2
Immunity to radiated electromagnetic field: acc. to EN 61000-4-3 Test characteristic: 80 - 1000 MHz; 80% AM
(1 kHz)
Immunity to fast electric transients (burst): acc. to EN 61000-4-4
Surge capability: acc. to EN 61000-4-5
Immunity to voltage dips, short interruptions and voltage variations.
Test acc. to EN 61000-4-11
Test performed at
Voltage dips
Assessment criteria
a. Agreed operational behaviour within the specified limits.
Discharge
characteristic
Air discharge
Contact
discharge
Indirect
discharge
Coupling
AC-input
DC-output
(capacitive
coupling clamp)
Surge voltage
1KV
Test level %
U
0
40
Firma / Company:
Gerätetyp / Typ
Art.-Nr. / Part-No.
Zeichnungs-Nr. / Draw.-No.
Immunity to conducted disturbances, induced by radio frequency fields: acc. to EN 61000-4-6
N
Test level
Test level
3V/m
3V
Voltage dips
and short
interruptions
100
60
Index / Rev.: ⓑ
Test level
±8KV
±4KV
±8KV
Test level
2KV
2KV
Distribution
FW7710/EU/0.7
1891526
15.3091.511-00
U
assessment criteria
Uin 120Vac
B
in
= 120Vac/230VAC
Assessment criteria
Assessment criteria
duration
time of
voltage dips
(in halfsine)
0.5
1
5
10
25
50
A
A
Assessment
criteria Uin
120Vac
B
B
B
assessment
criteria Uin
120Vac
B
B
Lfd. Nr. / Doc.-No. 81268
Test result
Uin 120Vac
A
B
B
B
B
B
assessment criteria
Uin 230Vac
B
assessment
criteria Uin
230Vac
B
B
Assessment
criteria
Uin 230Vac
B
B
B
Test result
Uin 230Vac
A
A
B
B
B
B
Liefervorschrift / Specification