RM0004N65 HAMMOND POWER SOLUTIONS, RM0004N65 Datasheet - Page 2

no-image

RM0004N65

Manufacturer Part Number
RM0004N65
Description
Line Reactor
Manufacturer
HAMMOND POWER SOLUTIONS
Series
RMr
Datasheet

Specifications of RM0004N65

Suppressor Type
Line Reactor
Power Consumption
13W
Supply Voltage Range
240VAC To 600VAC
Phase Type
3 Phase
Output Current
4A
Inductance
6.5mH
Switching Frequency
20kHz
Length
71.88mm
Width
111.76mm
Brand/series
RM Series
Current, Rating
4 A
Frequency, Operating
60 Hz
Impedance
5%
Power, Rating
0.5 HP
Standards
UL File No.: E61431, CSA File No.: LR 3902 and CE Mark (IEC 61558- 2-20-2000:)
Voltage, Rating
240 VAC
Height
86.36mm
Rohs Compliant
Yes
Power Rating
1hp
Supply Voltage
600V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SECTION 3
increased effi ciencies. The challenge for today’s designers is dealing with non linear wave shapes generated by
solid state devices.
expectancy and effi ciency of both the motor and the drive itself are signifi cantly enhanced.
ELIMINATE NUISANCE TRIPPING
tripping of circuit breakers. Furthermore, modern switchgear, equipped with solid state trip sensing devices, is
designed to react to peak current rather than RMS current. As switching transients can peak over 1000 volts, the
resulting overvoltage will cause undesirable interruptions. A reactor added to your circuit restricts the surge current
by utilizing its inductive characteristics, and therefore eliminates nuisance tripping.
EXTEND THE LIFE OF SWITCHING COMPONENTS
by the use of a Hammond line reactor.
SATURATION
not saturate under the most adverse line conditions. Since the inductance is linear over a broader current range,
equipment is protected even in extreme overcurrent circumstances.
EXTEND THE LIFE OF YOUR MOTOR
failures due to output circuit faults. Subsequently, motor operating temperatures are reduced by 10 to 20 degrees
and motor noise is reduced due to the removal of some of the high frequency harmonic currents.
LOW HEAT DISSIPATION
reactors with ideal operating features including low temperature rises and reduced losses. Hammond reactors will
operate effi ciently and heat dissipation in your equipment will be of minimal concern.
© Hammond Power Solutions Inc.
Utilizing Variable Speed Drives to control motor speed has impacted industry both in energy savings and
By choosing a Hammond line reactor, many line problems can be eliminated. Additionally, performance, life
Transients due to switching on the utility line and harmonics from the drive system, can cause intermittent
Due to the attenuation of line disturbances, the life of your solid state devices are extended when protected
Due to the care in the selection of the core material with its optimum fl ux density, Hammond line reactors will
Line reactors, when selected for the output of your drive, will enhance the waveform and virtually eliminate
Particular attention has been focused on the design and fi eld testing of this product line. The result is
Why Choose A Line Reactor ?
Normal sine wave from the Utility supply.
110
RM SERIES LINE REACTORS
Data subject to change without notice.

Related parts for RM0004N65