EZAEG3A50AV Panasonic, EZAEG3A50AV Datasheet - Page 3

ESD SUPPRESSOR, 0603, 15V, 0.1PF

EZAEG3A50AV

Manufacturer Part Number
EZAEG3A50AV
Description
ESD SUPPRESSOR, 0603, 15V, 0.1PF
Manufacturer
Panasonic
Series
EZAEG3r
Datasheet

Specifications of EZAEG3A50AV

Suppressor Type
Data Line
Voltage Rating
15V
Svhc
No SVHC (18-Jun-2010)
Capacitance
0.1pF
Clamping Voltage Vc Max
100V
Leakage Current
2mA
Operating Temperature Max
125°C
Inductor Type
ESD Suppressor
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EZAEG3A50AV
Manufacturer:
PANASONIC
Quantity:
150 000
Part Number:
EZAEG3A50AV
Manufacturer:
SRELEICS
Quantity:
20 000
Subject
Part No.
5.2.Electrical performance
5.3. Environmental performance
Characteristics
5.2.1
Capacitance
5.2.2.
Clamping Voltage
5.2.3.
Peak Voltage
5.2.4.
Leakage Current
Characteristics
5.3.1.
Rapid change of
temperature
5.3.2.
Humidity
5.3.3.
Load Life in
humidity
5.3.4.
Endurance
Specifications
0.1 ± 0.1 pF max.
100V max.
500V max.
1 microA max.
Specifications
max.
and no evidence of mechanical
damage
max.
and no evidence of mechanical
damage
max.
and no evidence of mechanical
damage
and no evidence of mechanical
damage
Leakage Current :10 micro A
Leakage Current :10 micro A
Leakage Current :10 micro A
Leakage Current :10 micro A
max.
ESD Suppressor
EZAEG3A
Panasonic Electronic Devices Co., Ltd.
Test Methods
Capacitance value shall be measured at the
conditions specified below.
Clamping voltage value shall be measured at 30ns
after initiation of pulse and measured at the
condition specified below.
Peak voltage value shall be measured at the
Leakage current value shall be measured at
DC15V.
Test Methods
Specimens shall be tested for 100 cycles
duty cycle.
Measurement shall be done in 48 hours± 4 hours
at “standard conditions” after the test.
Specimens shall be tested for 1000 hours +48/-0
hours in a humidity test chamber controlled at
40degC ± 2 degC and 90 % to 95 % relative
humidity.
Measurement shall be done in 48 hours ±4 hours
at “standard conditions” after the test.
Specimens shall be operated at rated voltage for
1000 hours +24/-0 hours in a humidity test
chamber controlled at 40degC ± 2degC and 90 %
to 95 % relative humidity.
Measurement shall be done in 48 hours ±4 hours
at “standard conditions” after the test.
Specimens shall be operated at rated voltage for
1000 hours +48/-0 hours at 85degC ± 2degC
ambient.
Measurement shall be done in 48 hours ±4 hours
at “standard conditions” after the test.
Frequency : 1MHz±10%
Voltage : 1Vrms±0.2Vrms
Temperature : 25degC±2degC
ESD test condition : IEC61000-4-2,8kV
condition specified below.
ESD test condition : IEC61000-4-2,8kV
continuously in accordance with the following
Step
1
2
3
4
+125 ± 2 degC
+25 ± 2 degC
+25 ± 2 degC
-55 ± 2 degC
Temperature
contact discharge
contact discharge
30min ± 5 min
30min ± 5 min
3min max.
3min max.
No.
151-ZA-EEG3-00B
PAGE
Time
9-3