MINI-PS-100-240AC/10-15DC/2 Phoenix Contact, MINI-PS-100-240AC/10-15DC/2 Datasheet - Page 4

no-image

MINI-PS-100-240AC/10-15DC/2

Manufacturer Part Number
MINI-PS-100-240AC/10-15DC/2
Description
POWER SUPPLY PRIMARY SWITCH MODE
Manufacturer
Phoenix Contact

Specifications of MINI-PS-100-240AC/10-15DC/2

Power Supply Type
Switch Mode
Power Supply Output Type
Fixed
No. Of Output Channels
1
Output Voltage
12VDC
Output Current
2A
Input Voltage
85V To 265V
Supply Voltage Typ
110VAC / 230VAC
No. Of Outputs
1
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power Supply, Primary Switch Mode, Narrow Design – MINI-PS-100-240AC/10-15DC/2
4. Device View, Connections, and Control Elements
1 1 1 1 AC input:
2 2 2 2 DC output:
3 3 3 3 DC OK LED
4 4 4 4 Potentiometer 10 - 15 V DC
5 5 5 5 Universal latching foot for EN DIN rails
5. Safety and Warning Instructions
and all functions can be used, please read these
instructions carefully.
To ensure that the device can be operated safely
Input voltage 85 - 264 V AC
Frequency 45 - 65 Hz
(0.2 mm
(0.2 mm
(25 - 14 AWG)
Internal fuse 2 AT
Recommended fuse
10 A or 16 A c.b./Characteristic B
Output voltage 12 V DC (default),
can be set from 10 - 15 V DC using potentiometer 4
(0.2 mm
(0.2 mm
The device is idling-proof and short-circuit-proof.
Caution: Never carry out work when the
power is turned on, this is highly
dangerous.
2
2
2
2
to 2.5 mm
to 2.5 mm
to 2.5 mm
to 2.5 mm
2
2
2
2
solid)
flexible)
solid)
flexible) (25 - 14 AWG)
1
3
PHOENIX CONTACT page 4 of 8
4
qualified personnel. The relevant country-specific
regulations (e.g., VDE, DIN) must also be observed.
that:
• The mains have been connected correctly and
• The device can be switched off outside the power
• All supply lines have sufficient fuse protection and
• All output cables are the correct size for the maximum
• Sufficient convection is ensured.
the terminal area must be covered to provide sufficient
protection against unauthorized access to live parts.
This is ensured by installing the device in the control
cabinet or distributor box.
and high levels of stored energy.
Installation and startup must only be carried out by
Before startup it is particularly important to ensure
protection is provided against electric shock.
supply according to EN 60950 regulations (e.g., by
the line protection on the primary side).
are the correct size.
device output current or have separate fuse
protection.
MINI POWER is a built-in device. After installation
The device contains dangerous live components
2
5
Figure 04