BXA10-48D12-SJ Emerson Network Power, BXA10-48D12-SJ Datasheet - Page 2

10W, 18-75Vin, Dual, ±12V@±0.4A, 2.0" X 1.0" X 0.4" Enclosed, 84% Eff, Remote On/Off, 3.4mm TH, RoHS 6

BXA10-48D12-SJ

Manufacturer Part Number
BXA10-48D12-SJ
Description
10W, 18-75Vin, Dual, ±12V@±0.4A, 2.0" X 1.0" X 0.4" Enclosed, 84% Eff, Remote On/Off, 3.4mm TH, RoHS 6
Manufacturer
Emerson Network Power
Datasheet

Specifications of BXA10-48D12-SJ

Product
Isolated
Output Power
5 W
Input Voltage Range
18 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
2
Output Voltage (channel 1)
12 V
Output Current (channel 1)
0.416 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
0.416 A
Isolation Voltage
1.5 KV
Package / Case Size
50.8 mm x 25.4 mm x 10.3 mm
Output Voltage
12 V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Specifications
All specifications are typical at nominal input, full load at 25
OUTPUT SPECIFICATIONS
Line regulation
Load regulation
Minimum load
Overshoot
Ripple and noise
(See Note 2)
Transient response
Temperature coefficient
Overvoltage protection
Short circuit protection
INPUT SPECIFICATIONS
Input voltage range
Input filter
Start up surge current
Remote ON/OFF
ON (See Note 3)
OFF
OFF idle current
Start-up time
LL to HL, single output
LL to HL, dual output
10% to 100% FL (See Note 4)
48 V models
12 V models
At start-up
5 Hz to 20 MHz
25% load step
Clamp type
Hiccup
12 Vdc (See Note 6)
48 Vdc
Resistive load
Open collector compatible
High impedance >400 kΩ
Low impedance <1.0 kΩ
100 mV pk-pk, max.
automatic recovery
No minimum load
±2.0% max. dev.,
250 μs recovery
±0.02%/°C max.
to within ±1.0%
10% full load
°
Continuous
20 mV rms
1.6 s, max.
C unless otherwise stated.
1.5 A max.
18-75 Vdc
10% max.
See table
9-18 Vdc
<1.5 mA
Pi type
±0.2%
±0.2%
±0.5%
EMC CHARACTERISTICS
Conducted emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
GENERAL SPECIFICATIONS
Efficiency
Isolation voltage
Switching frequency
Approvals and
standards
Case material
Material flammability
Weight
MTBF
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Relative humidity
Altitude
Vibration
EN55022, FCC (See Note 8)
EN61000-4-2, level 2
EN61000-4-2, level 3
EN61000-4-5, level 2
EN61000-4-4, level 2
EN61000-4-3, level 3
EN61000-4-6, level 3
Input/output
Input or output to case
Fixed
Safety
MIL-HDBK-217F
Bellcore
Operating ambient
(See derating curve)
Non-operating amb.
Case
Derating
Cooling
Non-condensing
Operating
Non operating
5-500 MHz
Black coated, six-sided metal case
Embedded Power for
Business-Critical Continuity
VDE0805, EN60950, IEC950
UL1950, CSA C22.2 No. 950
Free air convection cooled
2.5 G rms (approx.)
See derating curve
-55 °C to +125 °C
10,000 feet max.
40,000 feet max.
>2 million hours
-25 °C to +71 °C
519,000 hours
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
20 g (0.71 oz)
5% to 95% RH
+110 °C max.
1500 Vdc
1000 Vdc
See table
UL94V-0
400 kHz
Level A
Rev.03.07.07
bxa10
2 of 4

Related parts for BXA10-48D12-SJ