CPCI-A-3U-200C Murata Power Solutions Inc, CPCI-A-3U-200C Datasheet - Page 2

AC/DC CPCI 200W 3Ux8HP

CPCI-A-3U-200C

Manufacturer Part Number
CPCI-A-3U-200C
Description
AC/DC CPCI 200W 3Ux8HP
Manufacturer
Murata Power Solutions Inc
Series
cPCI-A-3U-200Cr
Datasheet

Specifications of CPCI-A-3U-200C

Voltage - Output
3.3V, 5V, ±12V
Number Of Outputs
4
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Compact PCI®
1st Output
5 VDC @ 25A
2nd Output
3.3 VDC @ 36A
3rd Output
12 VDC @ 5A
4th Output
-12 VDC @ 500mA
Size / Dimension
6.68" L x 1.59" W x 5.06" H (169.6mm x 40.3mm x 128.6mm)
Power (watts) - Rated
200W
Operating Temperature
-5°C ~ 50°C
Efficiency
80%
Approvals
CE, CSA, UL
Line Regulation
±0.5%
Load Regulation
±1%, ±4%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
811-1963
ENVIRONMENTAL CHARACTERISTICS
Parameter
Ambient Operating Temperature
Ambient Storage Temperature
Operating Humidity
Storage Humidity
Altitude
GENERAL CHARACTERISTICS
Parameter
Effi ciency
Switching Frequency
MTBF
Weight
PROTECTION
Parameter
Inrush Current Limit
Input Protection
Over-voltage Protection
Parameter
Output Overload Protection
Hot-Swap Capability
Output Fault Isolation
Thermal Shutdown
STATUS & CONTROL SIGNALS & INDICATORS
Name
Enable (EN#)
Output Inhibit (INH#)
Output Fault (FAL#)
Remote Sense (RS+, RS-)
Thermal Warning (DEG#)
Front Panel Power Indicator LED
www.murata-ps.com
Conditions/Response
230VAC
Internal line fuse
V1, V2, & V3 with latched shutdown
Conditions/Response
Outputs are individually protected against overloads and indefi nite short circuit with automatic recovery upon removal of the fault condition.
Protected by internal ORing diodes
Output isolation devices are present in all outputs to isolate faults within a failed power supply.
Automatic recovery upon restoration to operational temperatures
Description
Contact closure to external ground to start unit. On shortest pin (last make, fi rst break).
TTL –compatible signal inhibited with GND or TTL “0”.
TTL compatible signal ,open collector active low signal .Indicates one or more outputs below 90% of specifi ed rate.
Available on V1 & V2. Maximum voltage compensation for cable losses 200mV.
Open collector active low 10ºC before power supply shut down.
A single bi-color indicator LED
Green LED - indicates output in range
Red LED - indicates one or more outputs below 90% of specifi ed range.
Conditions
Full load with 250LFM forced air and derating linearly above 55°C to 70°C, by 2.5% per °C
Non-condensing
Non-condensing
Operating
Storage
Conditions
230Vac, full load
120Vac, full load
Main Converter
Calculated per Bellcore standard B332 Gb 30ºC
Unpackaged
cPCI-A-3U-200C Series
200W 3Ux8HP AC/DC CompactPCI™
Min
110
Min
-40
cPCI-A-3U-200C.A01 Page 2 of 4
-5
300
Min
Inception
Typ
Typ
800
Typ
80
76
68
40000
6000
Max
Max
130
6.3
50
55
85
95
95
Max
%V
Units
Units
A
A
Units
khrs
ºC
ºC
%
%
kHz
ft
ft
rms
rms
%
nom
g

Related parts for CPCI-A-3U-200C