EXB250-48S2V5J Emerson Network Power, EXB250-48S2V5J Datasheet

150W, 33-75Vin, Single, 2.5V @60A, 1/2 Brick, 88% Eff, RoHS 6

EXB250-48S2V5J

Manufacturer Part Number
EXB250-48S2V5J
Description
150W, 33-75Vin, Single, 2.5V @60A, 1/2 Brick, 88% Eff, RoHS 6
Manufacturer
Emerson Network Power
Datasheet

Specifications of EXB250-48S2V5J

Output Power
150 W
Input Voltage Range
33 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
1
Output Voltage (channel 1)
2.5 V
Output Current (channel 1)
60 A
Package / Case Size
2.28 in x 2.4 in x 0.5 in
Output Voltage
2.5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
EXB250 Series
The EXB250 is a new high efficiency, open-frame, isolated 165 Watt converter series in an
industry standard half-brick footprint. The EXB250 delivers very high output current at low
voltages, and excellent useable power density for today’s high end applications. The design takes
advantage of open frame construction to provide a low weight, low thermal impedance baseplate
design. The seven models in the series feature an input voltage range of 33 Vdc to 75 Vdc and
are available in output voltages of 12 V, 5 V, 3.3 V, 2.5 V, 1.8 V, 1.5 V and 1.2 V. The output voltage
on each model is adjustable from 90% to 110% of the nominal value. Typical efficiencies for the
models are 90% for the 3.3 V, 88% for the 2.5 V and 87% for the 1.8 V version. The EXB250
series also has a remote ON/OFF capability. Overcurrent and overvoltage protection features are
included as standard. With full international safety approval including EN60950 (TÜV Rheinland)
and UL/cUL1950, the EXB250 reduces compliance costs and time to market.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
DC-DC CONVERTERS
OUTPUT SPECIFICATIONS
Voltage adjustability
Set point accuracy
Line regulation
Low line to high line
Load regulation
Minimum load
Overshoot
Undershoot
Ripple and noise
Transient response
(See Note 1)
INPUT SPECIFICATIONS
Input voltage range
Input current
Input current (max.)
(See Note 3)
Input reflected ripple
Active high remote ON/OFF
Logic compatibility
ON
OFF
Undervoltage lockout
Start-up time
(See Note 6)
High efficiency topology, 90% typical at 3.3 V
Industry standard footprint
Wide baseplate temperature, -40 ˚C to +100 ˚C
(natural convection)
90% to 110% output trim
No minimum load
Overvoltage protection
Remote ON/OFF
Available RoHS compliant
1.2 V model
All other models
Full load to min. load
At turn-on and turn-off
1.2 V, 1.5 V (Z), 1.8 V (Z),
2.5 V (Z) and 3.3 V (Z) models
5 Hz to 20 MHz
48 Vin nominal
No load
Remote OFF
(See Note 5)
Power up
Power down
Power up
Remote ON/OFF
S i n g l e o u t p u t
72-165 W High Efficiency DC-DC Converters
Open collector ref to -input
Open circuit or >4.0 Vdc
within total error band
5.7 A max. @ Io max.
and Vin = 33-75 Vdc
350 mA (pk-pk) typ.
6% max. deviation
150 µs recovery to
90% to 110%
145 mA max.
60 mV pk-pk
±1.6% max.
±0.2% max.
±0.1% max.
±0.2% max.
35 mA max.
32.5 V (typ.)
30.5 V (typ.)
10 ms (typ.)
20 mV rms
33-75 Vdc
3 ms (typ.)
<1.2 Vdc
None
None
0%
EMC CHARACTERISTICS
Conducted emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure EN61000-4-3
Conducted (DC power)
Conducted (signal)
Input transients
GENERAL SPECIFICATIONS
Efficiency
Operational
Switching frequency
Approvals and
standards (See Note 4)
Material flammability
Weight
MTBF
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
EN55022 (See Note 2)
EN55022 (See Note 2)
EN61000-4-2
EN61000-4-2
EN61000-4-6
EN61000-4-6
ETS 300 132-2, ETR 283
Input/output
Input/baseplate
Fixed
Telcordia SR-332
@ 25 °C, 100% load
ground benign
Demonstrated
Operating baseplate -40 °C to +100 °C
temperature
Non-operating
File Name: exb250s.pdf Rev (02): 06 Dec 2005
SPECIFICATIONS
EN60950 (TÜV Rheinland)
8 kV (NP), 15 kV (NP)
2 YEAR WARRANTY
6 kV (NP), 8 kV (NP)
-40 °C to +125 °C
>2,000,000 hours
1,598,243 hours
400 kHz typ.
UL/cUL1950
73 g (2.6 oz)
10 V/m (NP)
1500 Vdc
1500 Vdc
10 V (NP)
10 V (NP)
See table
UL94V-0
Level A
Level B
TÜV
1

Related parts for EXB250-48S2V5J

EXB250-48S2V5J Summary of contents

Page 1

... Typical efficiencies for the models are 90% for the 3.3 V, 88% for the 2.5 V and 87% for the 1.8 V version. The EXB250 series also has a remote ON/OFF capability. Overcurrent and overvoltage protection features are included as standard. With full international safety approval including EN60950 (TÜ ...

Page 2

... LINE LOAD 84.0% ±0.2% ±0.2% EXB250-48S1V2J 85.5% ±0.1% ±0.2% EXB250-48S1V5J 87.0% ±0.1% ±0.2% EXB250-48S1V8J 88.0% ±0.1% ±0.2% EXB250-48S2V5J 90.0% ±0.1% ±0.2% EXB250-48S3V3J 91.7% ±0.1% ±0.2% EXB250-48S05J 92.0% ±0.1% ±0.2% EXB250-48S12J (8,9) RoHS Compliance J = Pb-free (RoHS 6/6 compliant) Pin Length of Standard Product Blank = 0.210 ” ...

Page 3

... Recommended Hole Pattern PIN CONNECTIONS PIN NUMBER FUNCTION 1 +Vin 2 Remote On/Off 3 No Function 4 -Vin 5 -Vout 6 -Sense 7 Trim 8 +Sense 9 +Vout   Application Note Longform Datasheet 0.500 [12.70] *0.21 [5.33] ALL DIMENSIONS IN INCHES [mm] www.artesyn.com File Name: exb250s.pdf Rev (02): 06 Dec 2005 3 ...

Related keywords