LPS124 Emerson Network Power, LPS124 Datasheet

no-image

LPS124

Manufacturer Part Number
LPS124
Description
15v 130W 3"x 5"
Manufacturer
Emerson Network Power
Type
Open Framer
Datasheet

Specifications of LPS124

Output Power Rating
80 W
Input Voltage
85 VAC to 264 VAC
Number Of Outputs
1
Output Voltage (channel 1)
15 V
Output Current (channel 1)
5.3 A
Mounting Style
Chassis
Dimensions
5 in L x 3 in W x 1.3 in H
Output Voltage
15V
Output Power (max)
80W
Input Frequency
47 to 440Hz
Efficiency
80%
Screening Level
Commercial
Product Length (mm)
127mm
Product Depth (mm)
76.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Pin Count
14
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Safety
TUV:
UL:
CSA
NEMKO: 60950
AUSTEL: 60950
CB:
CE:
Special Features
• Active power factor correction
• 3” x 5” footprint
• Less than 1U high
• EN61000-3-2 compliant
• Remote sense
• Power fail and remote inhibit
• Single wire current sharing
• Adjustable main output
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• 5 V Standby output
LPS120 Series
120 Watts
Total Power:
Input Voltage:
# of Outputs:
and 12V Fan output
60950
60950
60950
Certificate and report
Mark (LVD)
80 - 130 Watts
85 - 264 VAC
Single
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Efficiency:
EMI/RFI:
Power factor:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Fan output:
Standby outputs:
Hold-up time:
Overload protection:
Overvoltage protection: 20 - 35% above nominal output
Remote sense:
Logical Control
Power failure:
Remote inhibit:
Remote sense:
85 - 264 VAC ; 127 - 300VDC
47 - 440 Hz
40 A max., cold start @ 25 °C
80% typical at full load
FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B con-
ducted; VDE0878PT3 Class B conducted
0.99 typical
0 .5 mA @ 50/60 Hz, 264 VAC input
80 W for convection ; 130 W with 30CFM forced air
± 5% minimum on the main outputs
12 V @ 500mA - 5%, +7%
5V @ 500mA ± 5%
20ms @ 125 W load, 120 VAC input
Short circuit protection on all outputs. Case overload protected @
120 - 135% above rating
Compensates for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
T TL logic signal goes high 100 - 500 msec after main output; it goes low at
least 4 msec before loss of regulation
Requires a contact closure to disable the outputs, except 5 V standby.
C ompensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 09.15.09_12
LPS120 Series
1 of 3

Related parts for LPS124

LPS124 Summary of contents

Page 1

LPS120 Series 120 Watts Total Power 130 Watts Input Voltage 264 VAC # of Outputs: Single Special Features • Active power factor correction • 3” x 5” footprint • Less than 1U high • EN61000-3-2 compliant • Remote sense • Power fail and remote inhibit • Single wire current sharing • Adjustable main output • Built-in Class B EMI filter • Overvoltage protection • Overload protection • Thermal overload protection ...

Page 2

Environmental Specifications Operating temperature: 0° °C ambient derate each output as 2.5% per degree from 50° °C. -20 °C start up Storage temperature: -40 °C to +85 °C Electromagnetic Designed to meet EN61000-4; susceptibility: -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing Humidity: 10% to 95% RH IEC68-2-6 to the levels of Vibration: IEC721-3-2 > 550,000 hours at full load and MTBF demonstrated 25 °C ambient conditions Embedded Power for Business-Critical Continuity Mechanical Drawing 3.00 (76.2) 2.55 (64.8) 4.55 (115.6) V Adjust POT SK3 ...

Page 3

... Maximum Load Model Output Minimum with Convection Number Voltage Load LPS121 3 LPS122 LPS123 LPS124 LPS125 LPS128 Peak current lasting < 30 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line volt- age and load ranges. 4. When in parallel a 10% load is required for each power supply. Pin Assignments Connector LPS120 ...

Related keywords