PAH200S48-12 TDK Corporation, PAH200S48-12 Datasheet - Page 66

no-image

PAH200S48-12

Manufacturer Part Number
PAH200S48-12
Description
LAMBDA PART
Manufacturer
TDK Corporation
Datasheets

Specifications of PAH200S48-12

Rohs Compliant
YES

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PAH200S48-12
Manufacturer:
LAMBDA
Quantity:
32
Part Number:
PAH200S48-12
Manufacturer:
PRX
Quantity:
292
Part Number:
PAH200S48-12
Quantity:
60
PAH
B-208
〈Input 〜 Baseplate〉
PAH
 Storage Temperature
Please note that sudden temperature changes can cause
condensation buildup, and other harmful affects to each
terminal solder.
 Storage Humidity
High temperature and humidity can cause the terminals
on the module to oxidize. The quality of the solder will be-
come worse.
 Cooling Method
The operating temperature is specified by the baseplate
temperature. Various cooling methods are possible such
as using heatsink or chassis of the equipment. If the tem-
perature is very high, fan is recommended.
 Baseplate Temperature vs. Output Regulation
This is the output voltage change ratio when varying the
baseplate operation temperature.
 Withstand Voltage
The power module is designed to withstand 1.5kVDC be-
tween the input to the baseplate and input to output for
1 minute. In the case that the withstand voltage is tested
in the incoming goods test, etc., please set the limit of
the test equipment to 20 mA. The applied voltage must
be increased gradually from zero to the testing value, and
then decreased gradually at shutdown. Do not use a timer
where a pulse of several times the applied voltage can be
generated. This could cause damage to the module. Be
sure to short all the input and output pins as shown below.
1.5kVDC 1 min. (20mA)
Note: Please be sure to short all the input & output pins as
shown above.
75D24
Baseplate
Voltage
Tester
Baseplate
Voltage
Tester
+Vin
CNT
CASE
−Vin
+Vin
CNT
CASE
−Vin
+Vo1
−Vo1
+Vo1
−Vo1
+Vo1
−Vo1
+Vo1
−Vo1
TRM2
TRM1
TRM2
TRM1
〈Input 〜 Output〉
1.5kVDC
Note: Please be sure CASE is not shorted to any pins.
 Isolation Resistance
The isolation resistance is more than 100MΩ at 500VDC
when tested with a DC isolation tester between the out-
put and the baseplate. Make sure that during testing, the
isolation testers does not produce a high pulse when the
applied voltage is varied. Ensure that the tester is fully dis-
charged after the test.
 Vibration
Please refer to the power module mounting in the
PAH75D24 SERIES Handbook in order to achieve vibra-
tion level stated in the specification.
 Shock
Value for the conditions of our shipping and packaging.
 Others
The performance of a system with Power Module is influ-
enced according to various conditions -- PCBs, chassis,
mechanics, heat dissipation.
Please evaluate actual products, and confirm its perfor-
mance.
Please refer to "Power Module Application Note" for ther-
mal design and mounting direction.
Baseplate
Voltage
Tester
Baseplate
Voltage
Tester
Baseplate
Voltage
Tester
1 min. (20mA)
・All specifications are subject to change without notice.
+Vin
CNT
CASE
−Vin
+Vin
CNT
CASE
−Vin
+Vin
CNT
CASE
−Vin
+Vin
CNT
CASE
−Vin
+Vin
CNT
CASE
−Vin
+Vo1
−Vo1
+Vo1
−Vo1
+Vo1
−Vo1
+Vo1
−Vo1
+Vo1
−Vo1
+Vo1
−Vo1
TRM2
TRM1
TRM2
TRM1
TRM2
TRM1
+Vo1
−Vo1
+Vo1
−Vo1
+Vo1
−Vo1
+Vo1
−Vo1
TRM2
TRM1
TRM2
TRM1

Related parts for PAH200S48-12