PAQ50S48-1R8 TDK Corporation, PAQ50S48-1R8 Datasheet

no-image

PAQ50S48-1R8

Manufacturer Part Number
PAQ50S48-1R8
Description
LAMBDA PART
Manufacturer
TDK Corporation

Specifications of PAQ50S48-1R8

Rohs Compliant
YES

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PAQ50S48-1R8
Manufacturer:
LAMBDA
Quantity:
33
Part Number:
PAQ50S48-1R8
Manufacturer:
TDK-LAMBDA
Quantity:
488
Part Number:
PAQ50S48-1R8/B
Manufacturer:
LINFINITY
Quantity:
50 000
Part Number:
PAQ50S48-1R8/B
Manufacturer:
LAMBDA
Quantity:
20 000
Part Number:
PAQ50S48-1R8/PV
Manufacturer:
LAMBDA
Quantity:
1 000
Part Number:
PAQ50S48-1R8/V
Manufacturer:
IR
Quantity:
1 000
Open Frame
PA Q F e a t u r e s a n d B e n e f i t s
S p e c i f i c a t i o n s
Feature
ITEMS
Nominal Output Voltage
Max Output Current
Max Output Power
Efficiency (Typ.)
Input Voltage Range
Input Current (Typ.)
Output Voltage Accuracy
Output Voltage Range
Max Ripple & Noise
Max Line Regulation
Max Load Regulation
Over Current Protection
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Cooling
Isolation Voltage
Shock
Weight (Typ.)
Vibration
Size (W×H×D)
Warranty
Notes:
*1. At 48VDC, maximum output current, Air Velocity = 2m/s and Ta = +25°.
*2. 36 - 76VDC, constant load.
*3. No load - Full load, constant input voltage.
Industry Standard footprint/pinout
ASIC Design
Wide Range Operating Temperature (-40 to
High Efficiency 88% at 3.3V (PAQ50)
MODEL
(*1)
(*1)
(*1)
(*6)
(*6)
(*2)
(*3)
(*4)
(*5)
(*5)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mV
mV
mV
W
%
%
C
in
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
PAQ50S48-1R2
14.4
0.39
100
1.2
12
78
10
10
Amplitude 0.825mm Constant (Maximum 49.0m/s
100°C
)
Low=On, Open=Off (/P option: Low=Off, Open=On)
PAQ50S48-1R8
-20%, +10%
Non Operating, 10-55Hz (Sweep for 1min.)
Quarter Brick Power Supply Specifications
21.6
0.56
105% - 150% (Self-Recovering /V option)
120% - 140% (Self-Recovering /V option)
100
1.8
12
83
10
10
Convection Cooled / Forced air cooled
Benefit
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Central Office:
Broadband:
Remote Electronics: Fixed Local Loop, Fiber Optic
Customer Premise: PBX, PABX, Datacomm, Voice Systems,
Industrial
Input-Output : 1.5kVDC for 1min
*4. Inverter shutdown method, manual reset. Auto restart option available.
*5. Refer to derating curve.
*6 External components are needed for operation.
Allows for multi-sourcing
Reduces number of components
Supports Harsh Wireless Operating Environment
Reduce footprint area/Operation without heatsink
Low Voltage Outputs (1.2-5.0V)
Industry Standard Footprint & Pinouts
Safety Agency Approvals (UL1950, CSA22.2, CE, TUV)
Constant Current Limit (Auto Restarting)
Remote On / Off
ASIC Design to Reduce Component Count
1.45” x .33” x 2.3”
Ta= -40° - +85°
PAQ50S48-2R5
36 - 76VDC
2 years
0.75
20G
100
2.5
±1
12
30
85
10
10
50
ATM, Sonet, DSL, ISDN, Frame Relay, WDM
Switching Equipment, Routers
Transmission, Microwave Transmission,
Wireless Local Loop
Video Conferencing
ATE Test Equipment & Semi-Fab
PAQ50S48-3R3
2
) X, Y, Z 1 hour each
±15%
39.6
0.96
100
3.3
12
88
10
10
PAQ50S48-5
1.18
100
10
50
90
10
10
5

Related parts for PAQ50S48-1R8

Related keywords