RBC-12/17-D48P-C Murata Power Solutions Inc, RBC-12/17-D48P-C Datasheet - Page 3

DC/DC

RBC-12/17-D48P-C

Manufacturer Part Number
RBC-12/17-D48P-C
Description
DC/DC
Manufacturer
Murata Power Solutions Inc
Series
RBC-12/17-D48r
Type
With UVLOr
Datasheet

Specifications of RBC-12/17-D48P-C

Product
Isolated
Output Power
210 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
17 A
Isolation Voltage
2250 V
Package / Case Size
Quarter Brick
Output Voltage
12 V
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
36V To 75V
Power Rating
210W
Output Current
17A
Supply Voltage
48V
Dc / Dc Converter Case Style
DIP
Voltage - Input (min)
36V
Voltage - Input (max)
75V
Power (watts) - Manufacture Series
210W
Power (watts) - Max
204W
1st Output
12 VDC @ 17A
2nd Output
-
3rd Output
-
Voltage - Isolation
2.25kV (2250V)
Mounting Type
Through Hole
Package / Case
5-DIP Module, 1/4 Brick
Size / Dimension
2.30" L x 1.45" W x 0.42" H (58.4mm x 36.8mm x 10.7mm)
Operating Temperature
-40°C ~ 85°C
Efficiency
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Performance/Functional Specifi cations
Typical at T
Refer to required airfl ow and Derating curves for thermal specifi cations. [1]
Input Voltage Range
Recommended External Fuse
Start-up Threshold
Undervoltage shutdown
Overvoltage shutdown
Input Current, nominal
Input Current, V
Input Current, shut-down mode
Inrush Transient
Refl ected Ripple Current [2]
Internal Filter Type
Reverse Polarity Protection
Remote On/Off Control [5]
Total Output Power [3]
Setpoint Accuracy (50% load)
Extreme Accuracy [14]
Output Current [7]
Minimum Load
Ripple and Noise (20MHz bandwidth)
Line and Load Regulation [10]
Effi ciency
Isolation Voltage (Input/output)
Isolation Resistance
Isolation Capacitance
Isolation Safety Rating
Current Limit Inception (98% of V
Short Circuit Current [6]
Short Circuit Duration (+V
Overvoltage Protection
Max. Capacitive Loading (resistive load) 10,000μF, low ESR 0.02 Ohms
Temperature Coeffi cient
Dynamic Load Response
Start Up Time
Fixed Switching Frequency
Calculated MTBF [4]
Operating Case Temperature [13]
Positive Logic
Negative Logic
Current
(Input to baseplate)
(Baseplate to output)
(to within 3% of V
(V
(Remote On to Vout regulated)
IN
to V
A
= +25°C under nominal input voltage and full-load conditions unless noted.
OUT
regulated)
IN
= V
OUT
MIN
)
OUT
grounded) Continuous, no damage
Dynamic Characteristics
OUT
Environmental
)
Output
Input
36-75 Volts
20 Amp fast blow
35V
33.5V
None [note 12]
See ording guide
6.00A
6.5mA max.
0.05A
15mAp-p
L-C
None (see note 11), install external fuse
On = Open or +3.5 to +13.5 V.
Off = Gnd. Pin or 0 to +1V.
On = Gnd. Pin or 0 to +1V.
Off = Pin open or +3.5V to +13.5V.
2mA max.
210W max. [15]
±3% of V
11.4V min. to 12.6V max.
See ordering guide
No minimum load
See ordering guide
See ordering guide
See ordering guide
2250Vdc min.
1500Vdc min.
1500Vdc min.
100M:
1500pF
Basic
27A, after warm up
5 Amps
(hiccup autorestart – remove short for
recovery)
15Vdc max. via magnetic feedback
±0.02% per °C
75μsec, 50-75-50% load step
100μsec, 25-75-25% load step
60msec
60msec
225 ±25kHz
1,247,727 hours
+110°C max.
2
-seconds
NOMINAL
www.murata-ps.com
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10) Regulation specifi cations describe the deviation as the line input voltage or output load current is varied from a
(11) If reverse polarity is accidentally applied to the input, a body diode will become forward biased and will accept
(12) Input overvoltage shutdown on 48V input models is normally deleted in order to comply with certain telecom
(13) Note that the converter may operate up to +110°C PCB temperature with the baseplate installed. However,
(14) “Extreme accuracy” refers to all combinations of line and load regulation, output current, initial setpoint
(15) Vo = (11.64V to 12.36V)
Electronic Thermal Shutdown
Operating Temperature Range
Storage Temperature Range
Flammability
Relative Humidity
Safety Compliance
Electromagnetic Interference
Pin Material
Weight
conducted or radiated
These are stress ratings. Exposure of devices to any of these conditions may adversely
affect long-term reliability. Proper operation under conditions other than those listed in
the Performance/Functional Specifi cations Table is not implied.
Input Voltage:
Input Reverse-Polarity Protection
Output Current
Storage Temperature
Lead Temperature (soldering, 10 sec.)
(With Derating)
All models are tested and specifi ed with external 1 || 10uF ceramic/tantalum output capacitors and external
22uF input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our
test equipment and may not be required to achieve specifi ed performance in your applications. All models are
stable and regulate within spec under no-load conditions.
General conditions for Specifi cations are +25°C, VIN = nominal, VOUT = nominal, full load.
Input Ripple Current is tested and specifi ed over a 5 Hz to 20 MHz bandwidth. Input fi ltering is CIN = 33μF/100V
tantalum, CBUS = 220μF/100V electrolytic, LBUS = 12μH.
Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher
temperatures and/or lower airfl ow, the DC/DC converter will tolerate brief full current outputs if the total RMS
current over time does not exceed the Derating curve. All Derating curves are presented at sea level altitude. Be
aware of reduced power dissipation with increasing density altitude.
Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fi xed
conditions, TPCBOARD = +25°C, full output load, natural air convection.
The On/Off Control may be driven with external logic or by applying appropriate external voltages which are
referenced to Input Common. The On/Off Control Input should use either an open collector/open drain transistor
or logic gate which does not exceed +13.5V.
Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting.
The outputs are not intended to sink appreciable reverse current.
Output noise may be further reduced by adding an external fi lter. See I/O Filtering and Noise Reduction.
All models are fully operational and meet published specifi cations, including “cold start” at –40°C.
nominal midpoint value to either extreme.
considerable current. To ensure reverse input protection with full output load, always connect an external input
fuse in series with the +VIN input. Use approximately twice the full input current rating with nominal input
voltage.
reliability requirements. These requirements attempt continued operation despite signifi cant input overvoltage.
thermal self-protection occurs near +125°C and there is a temperature gradient from high power components.
Therefore, +100°C baseplate temperature is recommended to avoid thermal shutdown.
accuracy and temperature coeffi cient.
Power = (197.88W to 210.12W)
Continuous
Transient (100msec max.)
Quarter Brick, Regulated Bus Converters
RBC-12/17-D48 Series
Absolute Maximum Ratings
11 Apr 2011 MDC_RBC-12/17-D48.A03 Page 3 of 9
Physical
+125°C min.
-40ºC to +85ºC, See Derating curves
–55 to +125°C
UL94V-0
To 85% / +85°C
UL60950-1, CSA-C22.2 No.60950-1,
IEC/EN60950-1
EN55022/CISPR22
(may require external fi lters)
Copper alloy with gold plate over nickel underplate
1 ounce (28.4 grams)
75 Volts
100 Volts
None, see notes. Install external fuse.
Current limited. Devices can
withstand an indefi nite output short
circuit without damage.
–55 to +125°C
+280°C
email: sales@murata-ps.com

Related parts for RBC-12/17-D48P-C