UEI30-033-Q48P-C Murata Power Solutions Inc, UEI30-033-Q48P-C Datasheet
UEI30-033-Q48P-C
Specifications of UEI30-033-Q48P-C
Related parts for UEI30-033-Q48P-C
UEI30-033-Q48P-C Summary of contents
Page 1
... Application Notes Performance Data SIMPLIFIED SCHEMATIC Typical topology is shown. www.murata-ps.com UEI30 Series programmable logic and FPGA’s. No minimum load is required. For systems requiring controlled startup/shutdown, an external switch, transistor or digital logic may be used to activate the remote On/Off control. Remote Sense inputs compensate for resistive line drops at high currents ...
Page 2
... Positive “P” polarity is standard for Q12 models and optional special order for Q48 models. Negative “N” polarity is standard for Q48 models and optional special order for Q12 models. 105° C. 250° seconds www.murata-ps.com UEI30 Series 30W Isolated Wide-Range DC/DC Converters Input Effi ciency ...
Page 3
... AT PINS 1-6 1.800 (45.72 0.900 REF (22.86) #2 0.100 (2.54 UEI30 Open Frame 30W Package C80 Pin The Remote On/Off can be provided with either positive (P suffi negative (N suffi x) polarity. www.murata-ps.com UEI30 Series 30W Isolated Wide-Range DC/DC Converters Dimensions are in inches (mm shown for ref. only). ...
Page 4
... Device includes electronic over- temperature shutdown protection under normal operation. -55 to +125° C. See soldering specifi cations www.murata-ps.com UEI30 Series 30W Isolated Wide-Range DC/DC Converters Remote On/Off Control Internal Reverse Input Polarity On/Off ...
Page 5
... CAUTION: This product is not internally fused. To comply with safety agency certifi cations and to avoid injury to personnel or equipment, the user must connect an external fast-blow fuse to the input terminals. See fuse information. www.murata-ps.com UEI30 Series 30W Isolated Wide-Range DC/DC Converters Start-up Time Dynamic Load ...
Page 6
... Since these are isolated DC/DC converters, their outputs are “fl oating” with respect to their input. The essential feature of such isolation is ideal ZERO CURRENT FLOW between input and output. Real-world converters however do exhibit tiny leakage currents between input and output (see Specifi cations). www.murata-ps.com UEI30 Series CURRENT PROBE 1 +INPUT ...
Page 7
... Trim input and either the +Sense or –Sense terminals. (On some converters, an external user-supplied precision DC voltage www.murata-ps.com UEI30 Series 30W Isolated Wide-Range DC/DC Converters email: sales@murata-ps.com 03 Feb 2011 MDC_UEI Series 30W.A14 Page ...
Page 8
... On/Off is grounded or brought to within a low voltage (see Specifi cations) with respect to –V LOAD R TRIM DOWN Figure 6 – Trim adjustments to increase Output Voltage using a Fixed Resistor www.murata-ps.com UEI30 Series 30W Isolated Wide-Range DC/DC Converters Trim Up Trim Down <Connect trim resistor between Trim and +Sense> UEI30-033-Q12/-Q48 12775 5110 ( ...
Page 9
... Ground plane or power return bus Do not connect control transistor through remote power bus Figure 8 – On/Off Enable Control Ground Bounce Protection www.murata-ps.com 03 Feb 2011 MDC_UEI Series 30W.A14 Page UEI30 Series +VCC ON/OFF CONTROL -INPUT DC/DC Converter + Vin Preferred location of On/Off control ...
Page 10
... The United States MIL-HDBK method is for military and industrial applications. Please refer to a qualifi ed reliability engineer for more background. Model Number MTBF (Hours) UEI30-033-Q12N-C 2,676,902 UEI30-033-Q12N-C 2,123,124 UEI30-033-Q12P-C 2,733,781 UEI30-033-Q12P-C 2,142,206 UEI30-033-Q48N-C 3,416,592 UEI30-033-Q48N-C 3,172,548 UEI30-033-Q48P-C 3,427,027 UEI30-033-Q48P-C 3,193,652 UEI30-050-Q12N-C 2,531,509 UEI30-050-Q12N-C 2,207,508 UEI30-050-Q12P-C 2,554,127 UEI30-050-Q12P-C 2,229,031 UEI30-120-Q48N-C 3,072,461 UEI30-120-Q48N-C 2,510,927 UEI30-120-Q48P-C 2,900,319 UEI30-120-Q48P-C ...
Page 11
... IN Natural convection Ambient Temperature (ºC) www.murata-ps.com UEI30 Series 30W Isolated Wide-Range DC/DC Converters Maximum Current Temperature Derating @Sea Level (V = 12V, airfl from input to output) IN Natural convection 100 LFM 200 LFM 300 LFM 400 LFM ...
Page 12
... UEI30-050-Q48 6.1 6.0 5.9 5.8 5.7 5.6 5 www.murata-ps.com UEI30 Series 30W Isolated Wide-Range DC/DC Converters ( 24V, airfl from input to output) IN Natural convection Ambient Temperature (º 18V, transverse airfl ow) IN Natural convection 100 LFM 200 LFM 300 LFM ...
Page 13
... UEI30 Series 30W Isolated Wide-Range DC/DC Converters Power Dissipation vs. Load Current @ 25°C Vin = 36 V Vin = 24 V Vin = 12 V Vin = 9 V 0.7 0.9 1.1 1.3 1.5 1.7 1.9 Load Current (Amps) Maximum Current Temperature Derating @Sea Level (V = 36V, transverse airfl ...
Page 14
... UEI30 Series 30W Isolated Wide-Range DC/DC Converters Power Dissipation vs. Load Current @ 25°C Vin = 75V Vin = 48V Vin = 24V Vin = 18V 0.7 0.9 1.1 1.3 1.5 1.7 1.9 Load Current (Amps) Maximum Current Temperature Derating @Sea Level (V = 75V, transverse airfl ...
Page 15
... LFM 1.95 1.90 1.85 1. www.murata-ps.com UEI30 Series 30W Isolated Wide-Range DC/DC Converters Power Dissipation vs. Load Current @ 25°C Vin = 36 V Vin = 24 V Vin = 12 V Vin = 9 V 0.5 0.7 0.9 1.0 1.2 1.4 1.5 Load Current (Amps) Maximum Current Temperature Derating @Sea Level (V = 36V, transverse airfl ...
Page 16
... The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. www.murata-ps.com/locations UEI30 Series 30W Isolated Wide-Range DC/DC Converters Power Dissipation vs. Load Current @ 25°C Vin = 75V ...