AP1-1-72-502 AIRPAX, AP1-1-72-502 Datasheet - Page 11

CIRCUIT PROTECTOR, HYD-MAG, 1P, 240V, 5A

AP1-1-72-502

Manufacturer Part Number
AP1-1-72-502
Description
CIRCUIT PROTECTOR, HYD-MAG, 1P, 240V, 5A
Manufacturer
AIRPAX
Series
APr
Datasheet

Specifications of AP1-1-72-502

Input Voltage Vac
240V
No. Of Poles
1
Current Rating
5A
Interrupting Capacity
1kA
Dielectric Strength
1250Vrms
Trip Time
9s
Voltage Rating Vdc
50V
Trip Time Max
9sec
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
http://airpax.sensata.com/
Multi-pole units with mixed construction, poles numbered left
to right when viewed from terminal end ( Note F ) .
-0
-1
-1R
( Note D )
-1RC
( Note D )
-3
-4
Hook
Terminals
AP
UP
(Note A)
AP - MIL
(Note B)
3
1
2
1
12
112
Type
Internal Configuration
Third Decision
Poles
Second Decision ( Note C )
First
Decision
Screw
Terminals
7
17
117
Switch Only
(Omit 4th and 5th Decisions)
Series
Series with Auxiliary Switch
with pierced pin terminals
Series with Auxiliary Switch
with cane hook terminals
Shunt
Relay (5 amps max coil rating)
Fully sealed magnetic
circuit protector
Underwriters' Laboratories
recognized circuit
supplementary protector
/1 through /6 QPL per
MIL-PRF-39019
Single pole unit,
mounted with
3/8 threaded bushing
Two pole unit,
bushing plus (2) 6-32
threaded inserts
Three pole unit,
bushing plus (2)
6-32 threaded units
AP12 -1 -51-203-FM
Example:
*Instantaneous delays are not compatible with
inrush enhancement options and are not recommended
for general use.
1 2 3 4
-40
-41
-42
-49
-50
-51
-52
-59
-60
-61
-62
-64
-65
-69
-71
-72
-79
For addition of inertial delay, add an ìFî to any delay
number. Except 40, 50 & 60.
4
Fourth Decision
Hz and Delay
400Hz 150% instant trip*
400Hz short time delay
400Hz long time delay
400Hz 135% instant trip*
DC 150% instant trip*
DC short time delay
DC long time delay
DC 125% instant trip*
50/60Hz 150% instant trip*
50/60Hz short time delay
50/60Hz long time delay
50/60Hz high pulse,
short time delay (50/60Hz only)
50/60Hz high pulse,
long time delay (50/60Hz only)
50/60Hz 125% instant trip*
DC, 50/60Hz,
400Hz short time delay 135% trip
DC, 50/60Hz,
400Hz long time delay 135% trip
DC, 50/60Hz,
400Hz instant time delay 135% trip*
5
6
AP/UP, AP/MIL Series - Decision Tables
FM Approved (Factory Mutual Research)
Add –FM to part number to indicate FM
approval. FM approval is available for
Single Pole, Series Trip, UP type units only.
TA = –40ºC to +65ºC
Units < 10A are rated CL 1, DIV 2,
Units > 10A are rated CL 1, DIV 2,
6
Optional
Note: Standard current ratings listed.
For other ratings, please consult the factory.
5
Group ABCD, T6
Group ABCD, T4A
-1251
-1751
Code
Fifth Decision ( Note E )
Nominal Amperage Rating
-051
-101
-201
-251
-401
-501
-601
-751
-102
-202
-252
-302
-502
-702
-752
-802
-103
-123
-153
-173
-203
10.000
12.000
15.000
17.000
20.000
Amperes
1.000
1.250
1.750
2.000
2.500
3.000
5.000
7.000
7.500
8.000
.050
.100
.200
.250
.400
.500
.600
.750
86

Related parts for AP1-1-72-502