BA1-B034610121D Carling Technologies, BA1-B034610121D Datasheet - Page 4

CIRCUIT BREAKER, HYD-MAG, 1P, 277V, 10A

BA1-B034610121D

Manufacturer Part Number
BA1-B034610121D
Description
CIRCUIT BREAKER, HYD-MAG, 1P, 277V, 10A
Manufacturer
Carling Technologies
Series
Br
Datasheet

Specifications of BA1-B034610121D

Input Voltage Vac
277V
No. Of Poles
1
Current Rating
10A
Interrupting Capacity
5kA
Dielectric Strength
3.75kV
Trip Time
20s
Voltage Rating Vdc
80V
Mounting Type
Push-On
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
60
B-Series – General Specifications
Electrical
Maximum Voltage
Current Ratings
Standard Voltage Coils
Auxiliary Switch Rating
Insulation Resistance
Dielectric Strength
Resistance, Impedance
Pulse Tolerance Curves
277VAC 50/60 Hz, 80VDC
Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0, 30.0, 35.0,
40.0 and 50.0 amps. Other ratings
available, see ordering scheme.
DC - 6V, 12V; AC - 120V, other rat-
ings available, see ordering scheme.
SPDT; 10.1 AMPS - 250VAC,1.0A
65 VDC or 0.5A 80 VDC, 0.1 Amps -
125VAC (with gold contacts).
VDE-1.0 Amp - 125VAC.
Minimum of 100 Megohms at 500
VDC.
UL, CSA - 1500 V 50/60 Hz for one
minute between all electrically isolat-
ed terminals. B-Series circuit break-
ers comply with the 8mm spacing
and 3750V 50/60 Hz dielectric
requirements from hazardous volt-
age to operator accessible surfaces,
between adjacent poles and from
main circuits to auxiliary circuits per
Publications EN 60950 and VDE
0805.
Values from Line to Load Terminal -
based on Series Trip Circuit Breaker.
Mechanical
Endurance
Trip Free
Trip Indication
Physical
Number of Poles
Internal Circuit Config.
Weight
Standard Colors
Environmental
Designed and tested in accordance with requirements of specifi-
cation MIL-PRF- 55629 and MIL-STD-202 as follows:
Shock
Vibration
Moisture Resistance
Salt Spray
Thermal Shock
Operating Temperature
10,000 ON-OFF operations @ 6 per
minute; with rated Current and
Voltage.
All B-Series Circuit Breakers will trip
on overload, even when Handle is
forcibly held in the ON position.
The operating Handle moves posi-
tively to the OFF position when an
overload causes the breaker to trip.
1 - 6 poles at 30 Amps or less. 1
and 2 poles at 31 Amps thru 50
Amps.
Series, (with or without auxiliary
switch), Shunt and Relay with cur-
rent or voltage trip coils, Dual Coil,
Switch Only (with or without auxiliary
switch).
Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole.)
Housing- Black; Actuator - See
Ordering Scheme.
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition "I".
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C,
Test Condition A. Instantaneous and
ultrashort curves tested at 90% of
rated current.
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-98%
RH.
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
-40° C to +85° C
www.carlingtech.com