IULNK1-1-52-10.0 AIRPAX, IULNK1-1-52-10.0 Datasheet - Page 11

no-image

IULNK1-1-52-10.0

Manufacturer Part Number
IULNK1-1-52-10.0
Description
MAGNETIC HYDRAULIC CIRCUIT BREAKER
Manufacturer
AIRPAX
Series
IULr
Datasheet

Specifications of IULNK1-1-52-10.0

No. Of Poles
1
Current Rating
10A
Interrupting Capacity
7.5kA
Dielectric Strength
3.75kV
Trip Time
10s
Voltage Rating Vdc
80V
Trip Time Max
10sec
Trip Time Min
1sec
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
http://airpax.sensata.com/
mid-Trip Indication
Circuit protection, rapid fault location
and alarm capability are blended
together in the Airpax mid-trip
indication option. This option is
designed for automatic handle
movement to a middle position upon
electrical overload, allowing for easier
detection of the fault circuitand
minimizing downtime due to the
overload condition.
In the optional auxiliary switch
configuration, the switch allows an
alarm or signal to be forwarded when
the breaker trips and the handle
moves to the middle position. The
alarm can be disengaged by the
manual actuation of the handle to the
OFF position. Once the fault has been
corrected, the circuit breaker can be
reset to the ON position. The mid-trip
option is available in one, two or three
pole toggle handle packages and in
either standard panel screw or snap-in
mounting. Please see specification
tables of specific product for available
ratings.
Snap-In mounting
The snap-in mounting adapter allows for
simplified mounting of most IEL/LEL
toggle handle products. Prior to
shipment, the adapter is attached to the
circuit breaker during our final product
assembly, allowing you to securely snap
the unit into a rectangular panel cut-out.
This eliminates the need for panel
mounting hardware and associated
assembly costs.
Available for units up to three poles,
with or without an option handle
guard.
Note: Tolerance ± .015 [.39] unless noted.
Dimensions in brackets [ ] are millimeters.
Panel Mounting Detail
Tolerance ±.005 [.13] unless noted.
PANEL mOUNTING OPTIONS
# of Poles
1 pole
2 pole
3 pole
[52.35]
2.061
[17.45]
.687
IAL/IUL/IEL/LEL Series - Panel Mounting Options
MID-TRIP
POSITION
Dimension “A”
[81.79]
3.220
[19.30 ± .18]
[38.86 ± .18]
[57.91 ± .18]
1.530 ± .007
2.280 ± .007
[39.62]
.760 ± .007
1.560
BREAKER IN ON OR MANUALLY
TURNED OFF POSITION
[25.27]
Mid-Trip Handle
Positions
BREAKER IN MID-TRIP
POSITION (ELECTRICALLY
TRIPPED)
.995
NO
NC
NO
NC
C
C
Panel Thickness
[1.57 ± .13]
[1.57 ± .13]
[1.57 ± .13]
.062 ± .005
.062 ± .005
.062 ± .005
[44.45]
1.750
[74.63
2.938
(SEE TABLE)
DIM.“A”
±.007
±.18]
Panel Mounting
Detail
[63.37]
2.495
138