1110-F112-P1M1-3A ETA, 1110-F112-P1M1-3A Datasheet

CIRCUIT BREAKER, 3A

1110-F112-P1M1-3A

Manufacturer Part Number
1110-F112-P1M1-3A
Description
CIRCUIT BREAKER, 3A
Manufacturer
ETA
Series
1110r
Datasheet

Specifications of 1110-F112-P1M1-3A

Voltage Rating Vdc
28V
Voltage Rating Vac
250V
Fuse Current
3A
No. Of Poles
1
Mounting Type
Panel Mount
Approval Bodies
BUREAU VERITAS, CSA, EN60934, LLOYDS, SEMKO, UL, VDE
Breaking Capacity
RoHS Compliant
Current Rating
3A
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1110-F112-P1M1-3A
Manufacturer:
HONEYWELL
Quantity:
43
Current
rating (A)
0.05
0.08
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
1.2
1.5
1.8
Authority
VDE, BV
UL
CSA
Semko (EN 60934)
Single pole switch/thermal circuit breaker (M-type TO CBE to EN
60934) with tease-free, trip-free, snap action mechanism. Designed for
snap-in panel mounting utilising keyed round hole or industry standard
fuse-holder cut-out dimensions. Featuring an ergonomically styled two
colour actuator with indicator band clearly showing the tripped/OFF
position.
Approved to CBE standard EN 60934 (IEC 934).
Motors, transformers, solenoids, extra low voltage systems, household
and office machines, instrumentation, marine applications.
Please enquire for packaging quantities
Issue E
1110 - F1 1
Type No.
1110
Standard current ratings and typical internal resistance values
Approvals
Description
Typical applications
Ordering information
snap in panel mounting
Mounting
F1 panel thickness 0.8...1.6 mm
F2 panel thickness 1.8...3 mm
Number of poles
1
Internal
resistance ( )
442
123
110
1 pole protected
Actuator style
2
2 - P1 M1 - 0.5 A
27.8
12.4
7.0
4.5
3.1
2.3
1.7
1.1
0.71
0.41
0.38
black push button/white indicator ring, standard
Other indicator ring colours are available to special order
Terminal design
P1 blade terminals A6.3-0.8
Thermal Overcurrent Circuit Breaker 1110-...
Voltage ratings
AC 250 V; DC 28 V
AC 250 V
AC 125 V
DC 50 V
AC 250 V; DC 50 V
AC 250 V
Characteristic curve
M1
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
medium delay
Current ratings
0.05...16 A
Current
rating (A)
10
12
15
16
2
2.5
3
3.5
4
5
6
7
8
ordering example
Current ratings
0.05...16 A
0.05... 6 A
7
0.05...16 A
0.05...16 A
0.05...10 A
... 16 A
Internal
resistance ( )
0.25
0.19
0.12
0.09
0.07
0.05
0.04
0.02
0.02
0.02
0.02
0.02
0.02
Voltage rating
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
Dielectric strength
(IEC 664 and 664A)
Insulation resistance
Interrupting capacity I
Interrupting capacity
(UL 1077/EN60934 PC 1)
Degree of protection
(IEC 529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Technical data
operating area
cn
AC 250 V; DC 28 V
(DC 50 V to special order)
0.05...16 A
0.05...4 A: 10,000 operations at 1 x I
5 ...16 A: 6,000 operations at 1 x I
-20...+60 C
Rated impulse
withstand voltage degree
2.5 kV
reinforced insulation in operating area
Test voltage
AC 3,000 V
> 100 M
AC 250 V: 0.05...16 A
DC 28 V:
I
0.05... 6 A
7
0.05...16 A
operating area IP 40
terminal area IP 00
8 g (57-500 Hz) 0.61 mm (10-57 Hz),
to IEC 68-2-6, Test Fc,
10 frequency cycles/axis
30 g (11 ms)
to IEC 68-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
240 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 12 g
N
1110-F1..
...16 A
(DC 500 V)
0.05... 6 A
7
12 ...16 A
U
AC 250 V
AC 125 V
DC 50 V
...10 A
N
Pollution
2
10 x I
300 A
200 A
8 x I
1,000 A
1,000 A
1,000 A
N
N
N
N
41
1

Related parts for 1110-F112-P1M1-3A

1110-F112-P1M1-3A Summary of contents

Page 1

... Thermal Overcurrent Circuit Breaker 1110-... Description Single pole switch/thermal circuit breaker (M-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising keyed round hole or industry standard fuse-holder cut-out dimensions. Featuring an ergonomically styled two colour actuator with indicator band clearly showing the tripped/OFF position ...

Page 2

... Thermal Overcurrent Circuit Breaker 1110-... Dimensions 1110-F1.. / -F2.. When installing the circuit breaker apply pressure on bezel only 12.1 15.6 blade terminals DIN 46244-A6.3-0.8 Panel cut out 1110-F1..-P.M1-...A 1110-F2..-P.M1-...A +0.2 0.05 - 0.4 installation side 0.8 … 1.6 16 0.15 insertion force 20 N, removal force 120 N ...