Z109E GOSSEN METRAWATT, Z109E Datasheet

FUSE, FF, 1.6A, 700VAC

Z109E

Manufacturer Part Number
Z109E
Description
FUSE, FF, 1.6A, 700VAC
Manufacturer
GOSSEN METRAWATT
Datasheets

Specifications of Z109E

Voltage Rating Vac
700V
Fuse Current
1.6A
Breaking Capacity
50kA @ 700VAC
Fuse Size Metric
6.3mm X 32mm
Fuse Size Imperial
1/4 X 1.1/4"
Cartridge Fuse Material
Glass
Fuse Type Blowing Characteristic
Very
Fuse Size Code
3AG
Blow Characteristic
Fast Acting
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
METRAport
Folding Analog Multimeter
Applications
The multimeter is equipped with an indicator display and an
electronic amplifier. It can be used in a wide variety of practical
electronics applications, for example in R&D, manufacturing,
equipment operation, in the test lab and for service calls, as well
as for training and vocational education.
Description
The multimeter has 46 measuring ranges for direct and
alternating voltages of up to 600 V, alternating voltage levels from
-40 to +62 dB, direct and alternating current of up to 10 A and
resistances of up to 20 MΩ. It has a constant input resistance of
10 MΩ in all voltage measuring ranges.
The multimeter is calibrated in RMS values for periodic sinusoidal
quantities. It makes use of full-wave rectification for the evaluation
of the arithmetic mean value.
All measuring ranges can be selected with the central measuring
range selector switch. The ranges are laid out in a clear-cut
fashion around the selector switch.
The measuring device and the display unit are enclosed in two
separate housing components which are connected to each
other by means of a hinge which can be snapped into various
positions. In this way, the ideal angle for ease of reading can be
selected with the instrument in any position.
GOSSEN METRAWATT GMBH
9 voltage measuring ranges, V :
100 mV, 300 mV, 1 V, 3 V, 10 V, 30 V, 100 V, 300 V and 600 V
7 current measuring ranges, A :
10 µA, 100 µA, 1mA, 10 mA, 100 mA, 1A and 10 A
5 resistance measuring ranges: 1 Ω ... 2 kΩ/ 10 Ω ... 20 kΩ/
100 Ω ... 200 kΩ/ 1 kΩ ... 2 MΩ/ 10 kΩ ... 20 MΩ
9 level measuring ranges: -40 dB ... +62 dB
High input resistance of 10 MΩ
for no-load voltage measurement
Reflective scale in folding lid which can be tilted for easy
reading and provides transport protection as well,
accuracy class 1.5 =
Overload protection: 600 V
in all functions and range settings
Automatic battery shutdown when instrument is folded closed
3A
Several well coordinated safety devices protect the instrument
against damage caused by incorrect operation and overloading
within the specified overload limit values:
The instrument can be operated independent of mains current
with a commercially available 9 V flat cell battery. Long battery
service life is assured thanks to the minimal current consumption
of the instrument’s electronic components.
The multimeter’s rugged design provides for outstanding
protection where harsh mechanical stressing prevails. When
folded together, the instrument is provided with extra mechanical
protection for the measuring device, as well as for the display unit.
The connector jacks are protected against accidental contact.
Suitable measurement cables with 4 mm test probes are included
as standard equipment.
Applicable Regulations and Standards
IEC/EN 61010-1:2001
VDE 0411-1:2002
DIN EN 61326
VDE 0843, part 20
DIN EN 60529
DIN VDE 0470, part 1
300 V CAT III
600 V CAT II
IEC/EN 61010-1, second edition
Oversized precision resistors
Fuse link in combination with protective rectifier diodes
Overvoltage arrester / positive temperature coefficient
resistors (PTCs)
Safety requirements for electrical equipment for
measurement, control and laboratory use
Electrical equipment for control technology and
laboratory use – EMC requirements
Test instruments and test procedures
– Degrees of protection provided by enclosures (IP code)
3-349-302-03
1/4.04

Related parts for Z109E

Z109E Summary of contents

Page 1

... In this way, the ideal angle for ease of reading can be selected with the instrument in any position. GOSSEN METRAWATT GMBH 300 V CAT III 600 V CAT II IEC/EN 61010-1, second edition ...

Page 2

... V flat cell battery per IEC 6LR61 (6F22), alkaline manganese, zinc-carbon or NiCd rechargeable battery. With zinc-carbon: approx. 500 hours, with alkaline manganese: approx. 1000 hours, with NiCd: approx. 200 hours, in the Ω range: ¼ of specified service life Pointer must be within the battery test field. GOSSEN METRAWATT GMBH ...

Page 3

... SM16 Current Measuring Adapter HV3 High-Voltage Probe HV30 High-Voltage Probe METRAport Folding Analog Multimeter Type  METRAport 3A F822 SM16 HV3 Z3431...  3A Article Number M113A Z109E Z109A GTY 3172 095 P01 GTM 9070190E0002 GTZ 3431 001R0011 GTZ 3431 001R0001 GTZ 3431... 3 ...

Page 4

... A~ Z3514 Clip-on current transformer 1 ... 2000 A ~ ● Without restriction ■ WZ11/12 ... Edited in Germany • Subject to change without notice • PDF version available on the Internet Phone: +49-(0)-911-8602-0 GOSSEN METRAWATT GMBH Fax: Thomas-Mann-Str E-mail: info@gossenmetrawatt.com 90471 Nürnberg, Germany www.gossenmetrawatt.com Meas. Max. Transformation Category Wire Dia ...