GTCA26-101M-P02 Tyco Electronics, GTCA26-101M-P02 Datasheet

no-image

GTCA26-101M-P02

Manufacturer Part Number
GTCA26-101M-P02
Description
GAS DISCHARGE TUBE, 2P, 3KA, 700V
Manufacturer
Tyco Electronics
Series
GTCx26r
Datasheets

Specifications of GTCA26-101M-P02

Suppressor Type
Gas Discharge Tube (GDT)
Dc Breakover Voltage
100V
Impulse Sparkover Voltage
700V
Gdt Case Style
Axial Leaded
Impulse Discharge Current
90A
Spark Over Voltage
100V
Tolerance
±20%
Package / Case
Axial
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
308 Constitution Drive
Menlo Park, CA 94025-
1164
Phone: 800-227-4856
www.circuitprotection.com
GENERAL DESCRIPTION
APPLICATIONS
BENEFITS
SYMBOL
FEATURES
• Helps provide overvoltage fault protection against high energy surges
• Suitable for sensitive equipment due to excellent impulse sparkover response
• Suitable for high-frequency applications
• Highly reliable performance
• Crowbar device with low arc-voltage
• Low capacitance and insertion loss
• High accuracy spark-over voltages for high precision designs
• Tested per ITU K.12 recommendations
• Non-radioactive materials
• Telecommunications:
• Industrial Electronics and Commercial Electronics, such as
- Power Supplies, Surge Protectors, Alarm systems
- MDF modules, xDSL equipment, RF system protection
Specification Status: Released
Miniature Two Electrode Series
Raychem Circuit Protection Products
TYPICAL APPLI CATION SCHEMATIC
Overvoltage Protection Device
Gas Discharge Tube
PolySwitch
Device
DOCUMENT: SCD 25817
REV LETTER: E
REV DATE: JULY 8, 2008
PAGE NO.: 1 OF 5
PRODUCT: GTCx26
Device
SiBar

Related parts for GTCA26-101M-P02

GTCA26-101M-P02 Summary of contents

Page 1

... MDF modules, xDSL equipment, RF system protection • Industrial Electronics and Commercial Electronics, such as - Power Supplies, Surge Protectors, Alarm systems SYMBOL Gas Discharge Tube Overvoltage Protection Device Raychem Circuit Protection Products TYPICAL APPLI CATION SCHEMATIC PolySwitch PRODUCT: GTCx26 DOCUMENT: SCD 25817 REV LETTER: E REV DATE: JULY 8, 2008 PAGE NO ...

Page 2

... Series GT : Gas Tube Material C : Ceramic Type Leads A : Axial Leaded Number of Electrodes 2 : Two Diameter 6 : 6mm DEVICE MARKING EXAMPLE : GTCA26-231M-P05 Week of Manufacture Per Raychem Circuit Protection lot number system : E. First half of 2004 week 14 Surge Rating 2.5kA 05 : 5kA Product Family Voltage Designator 10 : 100 230 V ...

Page 3

... ELV Compliant DEVICE RATINGS AND CHARACTERISTICS DC Impulse Sparkover Sparkover Voltage Voltage Part Number @ 100V/s @ 100V / μs @ 1kV / μs GTCN26-101M-P02 100V ± 20% ≤ 500V GTCA26-101M-P02 GTCN26-231M-P05 230V ± 20% ≤ 500V GTCA26-231M-P05 GTCN26-351M-P05 350V ± 20% ≤ 600V GTCA26-351M-P05 Note 1. Insulation Resistance Gas Discharge Tube Overvoltage Protection Device -40° ...

Page 4

... Miniature Two Electrode Series 308 Constitution Drive Menlo Park, CA 94025- 1164 Phone: 800-227-4856 www.circuitprotection.com DIMENSIONS No Leads (GTCN26): Axial Leads (GTCA26): mm: in*: Gas Discharge Tube Overvoltage Protection Device Raychem Circuit Protection Products A MIN MAX MIN mm: 4.0 4.3 5.8 in*: 0.16 0.17 0.23 *Rounded off approximation ...

Page 5

... Tyco Electronics Corporation. All rights reserved. Gas Discharge Tube Overvoltage Protection Device Raychem Circuit Protection Products Bulk* ( vacuum bags) 200 -- * Bulk packaging only for GTCN26 **Tray packaging only for GTCA26 *** 5 bags **** 10 trays PRODUCT: GTCx26 DOCUMENT: SCD 25817 REV LETTER: E REV DATE: JULY 8, 2008 PAGE NO Tray** ...

Related keywords