GTCA28-302M-P01 Tyco Electronics, GTCA28-302M-P01 Datasheet - Page 2

no-image

GTCA28-302M-P01

Manufacturer Part Number
GTCA28-302M-P01
Description
GAS DISCHARGE TUBE, 2P, 10KA, 4KV
Manufacturer
Tyco Electronics
Series
GTCx28r
Datasheets

Specifications of GTCA28-302M-P01

Suppressor Type
Gas Discharge Tube (GDT)
Dc Breakover Voltage
3kV
Impulse Sparkover Voltage
4000V
Gdt Case Style
Axial Leaded
Impulse Discharge Current
5A
Spark Over Voltage
3000V
Tolerance
±20%
Package / Case
Axial
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
308 Constitution Drive
Menlo Park, CA 94025-1164
Phone: 800-227-4856
www.circuitprotection.com
PART NUMBERING
EXAMPLE:
DEVICE MARKING
EXAMPLE : GTCA28-102M-P03
Series
GT : Gas Tube
Material
C : Ceramic
Type
A : Axial Leaded
Number of Electrodes
2 : Two
Diameter
8 : 8mm
10 P 03 GN
Week of Manufacture
Surge Rating:
Product Family
Voltage Designator
Manufacturer Symbol
10x 10^2: 1000V
Per Raychem Circuit Protection
lot number system :
E.g. G = First half of 2004; N = week 14
01 : 1kA
03 : 3kA
High Voltage Two Electrode Series
GT C A 2 8 - 102 M - P 03
Raychem Circuit Protection Products
Overvoltage Protection Device
Gas Discharge Tube
Packaging
No Suffix: standard Tray packaging
-B: Bulk packaging (only upon special request)
Surge Rating
01 : 1kA (10 times 8 x 20μs)
03 : 3kA (10 times 8 x 20μs)
Product Family
Voltage Tolerance
K : ± 10%
L : ± 15%
M : ± 20%
Voltage Designator
102 : 10 x 10^2 = 1000V
152 : 15 x 10^2 = 1500V
212 : 21 x 10^2 = 2100V
242 : 24 x 10^2 = 2400V
272 : 27 x 10^2 = 2700V
302 : 30 x 10^2 = 3000V
312 : 31 x 10^2 = 3100V
402 : 40 x 10^2 = 4000V
DOCUMENT: SCD 25818
REV LETTER: I
REV DATE: JUNE 11, 2008
PAGE NO.: 2 OF 5
PRODUCT: GTCA28-xx2x-P0x