249-4-B-30-40-1-62-2 AIRPAX, 249-4-B-30-40-1-62-2 Datasheet

no-image

249-4-B-30-40-1-62-2

Manufacturer Part Number
249-4-B-30-40-1-62-2
Description
AIRPAX PART
Manufacturer
AIRPAX
Datasheet

Specifications of 249-4-B-30-40-1-62-2

Rohs Compliant
YES
Introduction
249 Power Selector System
Multi-Pole
Configurations
Operating Characteristics
Delay Curves
Specifications
Decision Tables
|
|
|
|
|
|
|
|
165
167
169
171
173
174
177
179
209/219/229/249/279 Series
Magnetic Circuit Protectors

Related parts for 249-4-B-30-40-1-62-2

249-4-B-30-40-1-62-2 Summary of contents

Page 1

... Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 209/219/229/249/279 Series Magnetic Circuit Protectors 165 | 167 | | 169 | 171 173 | 174 | | 177 | 179 ...

Page 2

... UL Standard 508, the 229, for supplementary protectors applications, which complies to UL Standard 1077, and the 299, a Special Construction version. 165 209/219/229/249/279 Series - Introduction 209/219/229/279 Series Hydraulic Magnetic Circuit Protectors Utilizing the hydraulic-magnetic principle, the 209 family adapts itself to local applications and environments. Temperature conditions, which affect fuses and other thermal devices, are not a concern ...

Page 3

... MTG. INSERT .160 MIN. SCREW DEPTH [4.06] .310 MAX. SCREW DEPTH [7.87] 3.0 MM ISO THD. OPTIONAL 209/219/229/249/279 Series - 209/219/229 Dimensions “A” 1.026 ± .010 [26.06 ± 3.30] 2.072 [52.63] Max 3.108 [78.94] Max 4.144 [105.26] Max 5.180 [131.57] Max 6 ...

Page 4

... The 249 Power Selector Breaker System combines magnetic-hydraulic branch circuit overload protection and a power system selector switch in one device. The 249 is designed to allow selection of any one of two, three or four independent power systems. This is accomplished with fool-proof sliding-gate handle covers. The number of sliding covers is one less than the number of power systems. With this arrangement impossible to switch “ ...

Page 5

... MAX. .530 [13.46] +.015 -.005 2.250 +0.38 [57.15] -0.13 1.125 [28.58 1 Screw Terminals DIMENSIONS Number of Poles 209/219/229/249/279 Series - 249 Power Selector Breaker System .125 .200 (TYP.) [3.18] [5.08] .485 [12.32] 5.800 [147.32] 2.156 4.844 [54.76] [123.04] 2.375 [60.32] 4.750 [120 ...

Page 6

... MM ISO THD. OPTIONAL 1 Screw Terminals .390 [9.91] 169 209/219/229/249/279 Series - 209/219/229 Multi-Pole Three Phase, Four Pole Includes Control Protector Remote shutdown of equipment is sometimes necessary or desirable in today’s sophisticated equipment. The 219 four pole assembly fills this need for three phase operation. Three of the four poles are designed for the circuit’ ...

Page 7

... Caution: Elongation of mounting holes may be necessary for units with more than 6 poles and units poles due to tolerance compounding http://airpax.sensata.com/ DIMENSIONS Number of Poles Width 1 1.026 ± .010 [26.06 ± .254] 2 2.072 [52.63] Max 3 3.108 [78.94] Max 4 4.144 [105.26] Max 5 5.180 [131.57] Max 6 6.216 [157.89] Max 209/219/229/249/279 Series - 209/219/229 Multi-Pole 170 ...

Page 8

... Maximum short circuit interrupting current is 5000 amperes. The 279 series available only in a series trip configuration. Please consult Sensata for specific application details. 171 209/219/229/249/279 Series - 229D (Marine) / 279 (Communications) 209/219/229 CONFIGURATIONS Series Trip The most popular configuration for magnetic protectors is the series trip, where the sensing coil and contacts are in series with the load being protected ...

Page 9

... SEE NOTE A 3.550 [90.17] 1.250 [31.75] .750 [19.05] .190 [4.83] 209/219/229/249/279 Series - Configurations LINE LOAD RELAY RELAY LINE COIL COIL LOAD Relay Trip Dual Coil LINE LOAD SHUNT LINE V. COIL Shunt Trip LOAD ...

Page 10

... No Trip . Trip 12 to 100 66 No Trip 70 to 800 Notes: *279 is available only with DC delays 173 209/219/229/249/279 Series - Operating Characteristics INRUSH PULSE TOLERANCE Delay 61, 62, 63 64, 65, 66 Note: These limits do not apply to dual coil and tapped coil units 150% 200% 400 ...

Page 11

... PERCENT OF RATED CURRENT 10000 1000 100 .01 .001 0 100 150 200 300 400 125 PERCENT OF RATED CURRENT 209/219/229/249/279 Series - 209/219/229 Delay Curves DELAY 61 500 600 700 800 900 1000 DELAY 62 500 600 700 800 900 1000 DELAY 63 500 600 700 800 ...

Page 12

... Series - Delay Curves 209/219/229/279 DELAy CURVES 60Hz Delay Curves (typ) 10000 1000 DELAY 64 100 .01 .001 0 100 150 200 300 400 500 600 125 PERCENT OF RATED CURRENT 10000 1000 100 .01 .001 0 100 150 200 300 400 500 600 125 PERCENT OF RATED CURRENT ...

Page 13

... PERCENT OF RATED CURRENT http://airpax.sensata.com/ DELAY 51 700 800 900 1000 DELAY 52 700 800 900 1000 DELAY 53 700 800 900 1000 209/219/229/249/279 Series - 209/219/229 Delay Curves 400Hz Delay Curves(typ) 10000 1000 DELAY 41 100 .01 .001 0 100 150 200 300 400 500 600 ...

Page 14

... M5 Stud Terminals 1 Stud Terminals Where applicable, mechanical support must be provide to the terminals when applying torque 177 209/219/229/249/279 Series - Specifications Trip Free Will trip open on overload, even when forcibly held on. This prevents the operator from damaging the circuit by holding Impedance (Ohms) the handle in the ON position. ...

Page 15

... UL/CSA VDE UL1077 & CSA VDE 1 .10-100 - U1, 5000 - 1 .10-100 - U1, 5000 - - - .10-100 - 4000 - - .10-100 - 4000 209/219/229/249/279 Series - Agency Approvals Rated Current (Amps) Interrupting Capacity (Amps) Frequency (Hz) Min. Poles UL VDE UL 508 DC 1 .10-100 .10-100 5000 50/60 2 .10-100 - 5000 50/60 2 .10-100 - 10000 50/60 1 .10-100 ...

Page 16

... If more than one auxiliary switch is speci- fied use “2R” through “6R” as required. 179 209/219/229/249/279 Series - Decision Tables C Line terminals are 10-32 screws for bus connection to 100 amperes. Load termi- nals are 10-32 screws to 50 amperes and solderless connectors from 50 to 100 amperes ...

Page 17

Terminal -1 Solderless connector -2 Solderless connector -2C Solderless connector -3 10-32 screw (100 amps max.) -3C 10-32 screw (100 amps max.) † -4 10-32 screw (50 amps max.) -5 10-32 screw (50 amps max.) -5C 10-32 screw (50 ...

Page 18

... Series - 249 Decision Tables 249 POWER SELECTOR BREAkER SySTEM DECISION TABLES How to Order To evolve a convenient ordering system for most applications, the following code has been developed system is required which is not covered below, please consult factory or describe in detail. The number shown as an example describes a 120 volt, three section system, such as may be used on a boat with a port and starboard shore power receptacle and an AC generator ...

Page 19

... This document is generated from the AIRPAX™ full-line catalog #2455005000 printed in USA, January 2011 BUSINESS CENTERS Sensata Technologies 807 Woods Road Cambridge, MD 21613, USA Phone: +1 410-228-1500 Brands: Airpax™ Sensata Technologies Inc. 529 Pleasant Street Attleboro, MA 02703, USA Phone: +1 508-236-3287 Brands: klixon™, Sensata Technologies™ ...

Page 20

... This document is generated from the AIRPAX™ full-line catalog #2455005000 printed in USA, January 2011 BUSINeSS CeNTeRS Sensata Technologies 807 Woods Road Cambridge, MD 21613, UsA phone: +1 410-228-1500 Brands: Airpax™ Sensata Technologies Inc. 529 Pleasant Street Attleboro, MA 02703, UsA phone: +1 508-236-3287 Brands: Klixon™, sensata technologies™ ...