T10A068 Littelfuse Inc, T10A068 Datasheet

no-image

T10A068

Manufacturer Part Number
T10A068
Description
T&R / SiBODTM AXIAL 50A - 68V STD IH
Manufacturer
Littelfuse Inc
Series
SIDACtor®r
Datasheet

Specifications of T10A068

Voltage - Breakover
90V
Voltage - Off State
65V
Voltage - On State
4V
Current - Peak Pulse (8 X 20µs)
100A
Current - Peak Pulse (10 X 1000µs)
50A
Current - Hold (ih)
150mA
Number Of Elements
1
Capacitance
50pF
Package / Case
DO-204AC, DO-15, Axial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
T10A SIDACtor® Device
Electrical Parameters
* For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. I
• I
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• V
• V
• Special voltage (V
Surge Ratings in Amps
* Current waveform in µs
** Voltage waveform in µs
Telecom Design Guide • © 2006 Littelfuse
T10A060B
T10A060E
T10A062
T10A068
T10A080B
T10A080E
T10A100
T10A110B
T10A110E
T10A120
T10A130
T10A140B
T10A140E
T10A180
T10A180B
T10A180E
T10A200
T10A220
T10A220B
T10A220E
T10A240
T10A270
T10A270B
T10A270E
R o HS
PP
DRM
S
Number *
is measured at 0.5 V/µs.
is a repetitive surge rating and is guaranteed for the life of the product.
Part
Series
is measured at I
A
S
and V
V
The bi-directional T10A devices are a through-hole technology SIDACtor protector. It is
intended for cost-sensitive telecommunication applications. This T10 SIDACtor series
enables equipment to comply with various regulatory requirements including GR 1089, ITU
K.20, K.21, and K.45, IEC 60950, UL 60950, and TIA-968-A (formerly known as FCC
Part 68).
DRM
DRM.
Volts
100
120
130
140
140
180
175
175
200
220
215
215
240
270
270
270
110
110
58
58
60
65
75
75
DRM
@ 5 µA
1.2x50 **
8x20 *
Amps
100
) and holding current (I
Volts
120
120
133
135
135
160
173
170
170
240
210
210
267
293
265
265
320
360
360
360
V
80
80
82
90
S
10x700 **
5x310 *
Amps
37.5
I
H
PP
) requirements are available upon request.
Volts
V
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
T
3 - 25
PP
applies to -40 °C through +85 °C temperature range.
10x1000 **
10x1000 *
Amps
mAmps
50
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
I
S
mAmps
120
180
150
150
120
180
150
120
180
150
150
120
180
150
120
180
150
150
120
180
150
150
120
180
50 / 60 Hz
I
H
Amps
I
TSM
30
TYP
www.littelfuse.com
Amps/µs
pF
50
50
50
50
43
43
43
38
38
38
38
34
34
34
32
32
30
30
30
30
30
30
30
30
di/dt
100

Related parts for T10A068

T10A068 Summary of contents

Page 1

... K.20, K.21, and K.45, IEC 60950, UL 60950, and TIA-968-A (formerly known as FCC Part 68). Electrical Parameters Part µA V DRM Number * Volts Volts T10A060B 58 80 T10A060E 58 80 T10A062 60 82 T10A068 65 90 T10A080B 75 120 T10A080E 75 120 T10A100 100 133 T10A110B 110 135 T10A110E 110 135 T10A120 120 ...