March 2009
DeviceNet Connectivity
The PanelMate DeviceNet implementation features the ability
to “monitor” status from other slave devices without the
need for active involvement from the master device. When
installed on DeviceNet, PanelMate can update its screens
with data from the slave devices or from the PC. It can also
input control (pushbutton) operations or numeric informa-
tion to the PC. These capabilities permit PanelMate units to
function as complete control and monitoring stations on
DeviceNet.
Table 48-39. DeviceNet Interface
General Electric Connectivity
GE Fanuc GEnius I/O Interface to GE PLCs
This interface provides a communication port for connection to
GE Series 6 and Series 90 PLCs over the GEnius I/O Network.
Table 48-40. GEnius I/O Interface
General Electric Communication Cables
PLC Interface Cables for PanelMate Power Pro 1100, 1700,
3000, 5000 or e-Pro
One 15-foot (4.6 m) cable, unless otherwise stated, for commu-
nications between a PanelMate 1100, 1700, 3000, 5000 or
ePro unit serial port and the PLC communications port using
D-Shell connectors. Cables used with PanelMate ePro require
a DB9(M)/DB9(F) converter (converts DB9(M) to DB9(F)).
Table 48-41. PLC Interface Cables for PanelMate Power Pro 1100, 1700,
3000, 5000 or ePro
Mitsubishi Connectivity
Mitsubishi Communication Cables
PLC Interface Cables for PanelMate Power Pro 1100, 1700,
3000, 5000 or ePro
One 15-foot (4.6 m) cable, unless otherwise stated, for commu-
nications between a PanelMate 1100, 1700, 3000, 5000 or
ePro unit serial port and the PLC communications port using
D-Shell connectors. Cables used with PanelMate ePro require
a DB9(M)/DB9(F) converter (converts DB9(M) to DB9(F)).
CA08102001E
Description
For all PanelMate Power Pro 1100, 1700,
3000, 5000
Description
GEnius I/O Interface
For all PanelMate Power Pro 1100, 1700,
3000, 5000
Description
Series 90 Programming Port
Series 90 (RS-422) Com 311/711 Module
Series 90 (RS-232) Com 311/711 Module
Series 6/6+ (RS-422) Com 2 – J1 Port
Series 6/6+ (RS-232) Com 2 – J2 Port
Number
1245DN
Number
1243
Number
GE21A
GE22
GE23
GE24
GE25
Catalog
Catalog
Catalog
For more information visit: www.eaton.com
Operator Interface Products
PanelMate Operator Interface
Connectivity: Utilities, Interfaces and Cables
Price
U.S. $
Price
U.S. $
Price
U.S. $
Table 48-42. PLC Interface Cables for PanelMate Power Pro 1100, 1700,
3000, 5000 or ePro
Modicon Connectivity
Modicon Modbus Plus PLC Network Upload/Download
“One-time use” diskette enables the PanelMate unit to
upload and download PanelMate configurations to PCs via
Modicon Modbus Plus PLC networks. This Upload/Down-
load feature can be used to conduct the following operations
without having to disconnect the PanelMate Unit from the
PLC, or open the enclosure to access the serial ports:
Table 48-43. Modicon Modbus Plus Network Upload/Download
Modbus Plus Communications and PanelMate
This interface provides a communication port for connection
to Modicon PLCs over the Modbus Plus network. Interface
mounts to the back of the online unit and can be mounted in
a 4-inch (102 mm) deep enclosure.
Table 48-44. Modbus Interface
Modicon Communication Cables
PLC Interface Cables for PanelMate Power Pro 1100, 1700, 3000,
5000 or ePro
One 15-foot (4.6 m) cable, unless otherwise stated, for commu-
nications between a PanelMate 1100, 1700, 3000, 5000 or
ePro unit serial port and the PLC communications port using
D-Shell connectors. Cables used with PanelMate ePro require
a DB9(M)/DB9(F) converter (converts DB9(M) to DB9(F)).
Table 48-45. PLC Interface Cables for PanelMate Power Pro 1100, 1700,
3000, 5000 or ePro
Description
A Series — AJ71C24 Module (RS-232)
A Series — AJ71C24 Module (RS-422) Cable
FX/FXo Series — (RS-232/RS-422) Converter
Description
One-time use diskette. Enables upload/down-
load on operator station. To operate,
customer requires:
1) Modbus Plus Interface (1248) to be installed
2) Windows Configuration Software OR
Description
Direct Modbus Plus Interface
PanelMate Power Pro 1100, 1700, 3000, 5000
Description
9-Pin Modbus
Micro PLC (RJ-45) Modbus Cable
Download configurations from a PC in a central location
to PanelMate units on a network.
Upload PanelMate configurations (while units are
monitoring and controlling) to a PC for backup.
Download new PanelMate software enhancements to units.
Note: Requires Modbus Plus Interface, Configuration Software
or Transfer Utility.
in unit
Transfer Utility on the PC
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1
Catalog
Number
MI21
MI22A
MI23
Catalog
Number
0548
Catalog
Number
1248
Catalog
Number
MB21
MB22
Price
U.S. $
Price
U.S. $
Price
U.S. $
Price
U.S. $
48-33
48

Related parts for ELCSOFTGP