H7AN2DAC100240 Omron, H7AN2DAC100240 Datasheet - Page 12

COUNTER DIGITAL LED

H7AN2DAC100240

Manufacturer Part Number
H7AN2DAC100240
Description
COUNTER DIGITAL LED
Manufacturer
Omron
Datasheet

Specifications of H7AN2DAC100240

Rohs Compliant
YES
Digit Height
72mm
Supply Voltage Range
100VAC To 240VAC
Counting Speed
30Hz
Operating Temperature Range
-10°C To +55°C
No. Of Digits / Alpha
2
H7AN-RW6D, -RW6DM
Arrangement and Functions of
Specification Selection Switches
H7AN-RW6D
SW1: (B) Counting function selector
SW2: (B) Operating mode selector
SW3-1: CP1 maximum counting
SW3-2: SW3-2: CP2 maximum
SW4-1: Output phase selector for first
SW4-2: Output phase selector for
SW4-3: Set value read selector
SW4-4: Manual reset selector
H7AN-RW6DM
SW1: (B) Counting function selector
SW2: (B) Operating mode selector
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
SW3-3: Power failure memory backup
SW4-1: Output phase selector for
SW4-2: Output phase selector for
SW4-3: Set value read selector
SW4-4: Manual reset selector
speed selector
counting speed selector
transistor output section
second transistor output section
speed selector
speed selector
first transistor output section
second transistor output section
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
L→H (at count-out)
(See note 1.)
H→L (at count-out)
L→H (at count-out)
(See note 1.)
H→L (at count-out)
Always read (See note 1.)
Read only at reset
Manual reset possible
(See note 1.)
Manual reset not possible
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
Memory backup (See note 1.)
No memory backup
L→H (at count-out)
(See note 1.)
H→L (at count-out)
L→H (at count-out)
(See note 1.)
H→L (at count-out)
Always read (See note 1.)
Read only at reset
Manual reset possible
(See note 1.)
Manual reset not possible
SW3
1
1
SW3
2
2
3
SW1 SW2
SW1 SW2
1
1
SW4
SW4
2
2
Indicator lights when
reset input is received
Pushbutton switch
for manual reset
Internal Unit mounting screw
One-shot timer adjuster
Front cover
Seven-segment LED
digital display
Indicator lights at count-out
3 4
3 4
Arrangement and Functions of Specification Selection Switches
H7AN-T4
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
SW4-1: Manual reset selector
SW4-2: UP/DOWN selector
H7AN-T4M
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
SW3-3: Power failure memory backup
SW4-1: Manual reset selector
SW4-2: UP/DOWN selector
speed selector
speed selector
speed selector
speed selector
H7AN-T4, -T4M, -ET4, -ET4M
H7AN-RT6, -RT6M, -RT8, -RT8M
Totalizing Counter
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
Manual reset possible
(See note 1.)
Manual reset not possible
Up counting (incrementing)
(See note 1.)
Down counting
(decrementing)
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
Memory backup (See note 1.)
No memory backup
Manual reset possible
(See note 1.)
Manual reset not possible
Up counting (incrementing)
(See note 1.)
Down counting (decrementing)
SW3
1
1
SW3
2
2
3
SW4
1
SW4
1
2
2
Note: 1. These settings are the defaults for the specification selection
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum
Indicator lights when reset input is received
Pushbutton switch for manual reset
Internal Unit mounting screw
Front cover
H7AN-ET4
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
H7AN-ET4M
SW1: (A) Counting function selector
SW3-3: Power failure memory backup
SW4: Manual reset selector
Seven-segment LED digital display
SW1: (A) Counting function selector
SW4: Manual reset selector
2. Specifications selected using the internal specification selection
speed selector
speed selector
speed selector
counting speed selector
switches.
switches become after switching once a reset has been
performed (e.g., power supply reset, external reset, or manual
reset, but not automatic reset).
If a reset is not performed, operation will continue with the
specifications before switching.
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
Memory backup (See note 1.)
No memory backup
Manual reset possible
(See note 1.)
Manual reset not possible
Manual reset possible
(See note 1.)
Manual reset not possible
SW3
1
1
SW3
2
2
3
SW1
SW1
SW4
SW4
1
1
H7AN-RT6, -RT8
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
H7AN-RT6M, -RT8M
SW1: (B) Counting function selector
SW3-1: CP1 maximum counting
SW3-2: CP2 maximum counting
SW1: (B) Counting function selector
SW3-3: Power failure memory backup
SW4: Manual reset selector
SW4: Manual reset selector
speed selector
speed selector
speed selector
speed selector
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
30 Hz (See note 1.)
5 kHz
Memory backup (See note 1.)
No memory backup
Manual reset possible
(See note 1.)
Manual reset not possible
Manual reset possible
(See note 1.)
Manual reset not possible
SW3
1
1
SW3
2
2
3
SW1
SW1
SW4
SW4
1
1
H7AN
12

Related parts for H7AN2DAC100240